EasyManuals Logo
Home>Emerson>Measuring Instruments>Daniel Series

Emerson Daniel Series User Manual

Emerson Daniel Series
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #77 background imageLoading...
Page #77 background image
7 Testing
7.1 Test the turbine meter
7.1.1 Commission the turbine meter
After installation, commission the turbine meter to ensure that the equipment is working
properly.
Procedure
1. Inspect all electrical connections to ensure compliance with electrical codes and
safety regulations.
2. Inspect all flange bolts used to secure the turbine meter in-line to ensure that
correct mounting procedures are followed and that flange connections are leak-
free.
3. Evaluate the system setup to ensure that all components are in the correct
sequence for accurate product measurement: isolation valve, strainer, flow
straightener, turbine meter, downstream section, control valve, etc.
4. Ensure that the supply voltage to the preamplifier is within the 10-30 VDC range.
User manual Testing
P/N 3-9008-515 March 2019
User manual 77

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Daniel Series and is the answer not in the manual?

Emerson Daniel Series Specifications

General IconGeneral
BrandEmerson
ModelDaniel Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals