DVC6000 Digital Valve Controllers
September 2013
8-4
Key Description Part Number
43* Cover Assembly (includes cover screws)
Standard 38B9580X022
Extreme temperature option (fluorosilicone elastomers)
Aluminum Construction 38B9580X032
Stainless Steel Construction 38B9580X042
48 Nameplate
49 Screw, self tapping (2 req’d)
(13)
63 Lithium grease (not furnished with the instrument)
64 Anti−seize compound (not furnished with the instrument)
65 Lubricant, silicone sealant (not furnished with the instrument)
154 Retaining Ring
(2)
(3 req’d)
237 Module Base Seal
(1)
Module Base
DVC6010, DVC6020, DVC6030, DVC6005
(see figures 8-2, 8-3, 8-4, 8-5, and 8-6)
2 Module Base
(13)
11 Drive Screw
(13)
(2 req’d)
12 O−ring
(1)
19 Label, Shield Assembly
(13)
61 Pipe Plug, hex socket
(13)
(3 req’d)
236 Screen, for single−acting direct units only
(13)
243 Flame Arrestor Assy
(13)
(3 req’d)
I/P Converter Assembly
DVC6010, DVC6020, DVC6030, DVC6005
(see figures 8-2, 8-3, 8-4, and 8-5)
23 Cap Screw, hex socket, SST
(2,16)
(4 req’d)
39* O−ring
(1,10)
41 I/P Converter
(10)
169 Shroud
(10,16)
210* Boot, nitrile
(1,10)
(2 req’d) (also see figure 7-3)
231* Seal Screen
(1,8,10)
Relay
DVC6010, DVC6020, DVC6030, DVC6005
(see figures 8-2, 8-3, 8-4, and 8-5)
24* Relay Assembly, (includes shroud, relay seal, mounting screws)
Standard
Single−acting direct (relay C) 38B5786X132
Double−acting (relay A) 38B5786X052
Single−acting reverse (relay B) 38B5786X092
Low Bleed
Single−acting direct (relay C) 38B5786X152
Double−acting (relay A) 38B5786X072
Single−acting reverse (relay B) 38B5786X112
Extreme Temperature option (fluorosilicone elastomers)
Standard Bleed
Single−acting direct (relay C) 38B5786X142
Double−acting (relay A) 38B5786X032
Single−acting reverse (relay B) 38B5786X102
Low Bleed
Single−acting direct (relay C) 38B5786X162
Double−acting (relay A) 38B5786X082
Single−acting reverse (relay B) 38B5786X122
Figure 8-1. Terminal Box of Natural Gas Certified
FIELDVUE DVC6000 Digital Valve Controller
GAS−BLOCKING
PRESS−FIT ADAPTOR
WIRING CONNECTOR
W9528
Key Description Part Number
Terminal Box
DVC6010, DVC6020, DVC6030, DVC6005
(see figures 8-1, 8-2, 8-3, 8-4, and 8-5)
4 Terminal Box Cap
(18)
34* O−ring
(1,9,18)
36* O−ring
(1,9,18)
44 Wire Retainer, pl stl
(2)
(6 req’d) (not shown)
58 Set Screw, hex socket, SST
(2,18)
72 Cap Screw, hex socket, SST
(2,18)
164 Terminal Box Assembly
(9)
Feedback Connections Terminal Box
DVC6005 (see figure 8-5)
4 Terminal Box Cap
(18)
34* O−ring
(1,9,18)
36* O−ring
(1,9,18)
44 Wire Retainer, pl stl
(2,19)
(5 req’d) (not shown)
58 Set Screw, hex socket, SST
(2,18)
62 Pipe Plug, hex hd, SST
(18)
72 Cap Screw, hex socket, SST
(2,18)
(3 req’d)
262 Adapter
(18)
263* O−ring
(18)
Standard 1F463606992
Extreme temperature option, (fluorosilicone) 1F4636X0092
264 Terminal Box Assembly, remote
(18)
8
*Recommended spare
1. Available in the Elastomer Spare Parts Kit
2. Available in the Small Hardware Spare Parts Kit
8. Available in the Seal Screen Kit
9. Available in the Terminal Box Kit
10. Available in the I/P Converter Kit
13. Available in the Spare Module Base Assembly Kit
16. Available in the Spare Shroud Kit
18. Available in the Remote Terminal Box Kit
19. Available in Feedback Unit Kit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Fisher FIELDVUE DVC6000 and is the answer not in the manual?

Emerson Fisher FIELDVUE DVC6000 Specifications

General IconGeneral
BrandEmerson
ModelFisher FIELDVUE DVC6000
CategoryController
LanguageEnglish

Related product manuals