5. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.
IQ8HC-72-M-INT Microinverter parameters
Features and specifications
Compatibility
54-cell/108-half-cell, 60-cell/120-half-cell, 66-
cell/132-half-cell, 72-cell/144-half-cell
Dimensions (without mounting brackets)
″
″
″
IP Rating Outdoor - IP67
Torque specifications for fasteners
• 6 mm mounting hardware: 5 N m
•
8 mm mounting hardware: 9 N m
Natural convection - No fans
Approved for wet locations
http://enphase.com/warranty
IQ8HC-72-M-INT Microinverter parameters
Compliance
AS/NZS 4777-2:2020
6
Safety:
EN IEC 62109-1, EN IEC 62109-2
EMC:
EN IEC 61000-3-2, 61000-3-3, 61000-6-2, 61000-6-
3, EN IEC 50065-1, 50065-2-1
EN55011 (At STC within MPP range)
Earthing
The DC circuit meets the requirements for ungrounded
PV arrays. Ground fault protection (GFP) is integrated
into the class II double-insulated microinverter.
Monitoring
Enphase Installer Platform and Enphase App
monitoring options. Both options require an IQ
Communication Power line communication (PLC)
6. Minimum two IQ8 Series Microinverters shall be required in the system.