AFTER INSTALLATION THE END USER SHOULD
KEEP THIS GUIDE FOR FUTURE REFERENCE
DO NOT
THROW AWAY
8
5
6
7
5. Select up to three 100mm extract spigot locations. If more than
three are required you will need to order extra spigots (see spares on
page 16). Slice around the edge of the chosen positions with a sharp
knife then knock out the blanks with a light tap and discard them. It
may be necessary to remove excess material with the knife.
6. If a spigot hole is removed in error use the spare blank provided to
cover the hole and glue it in place.
7. Push then twist a spigot into each of the cut holes and secure it to the
unit through the two screw holes with the self-tapping screws provided.
8. Ducts must be attached securely to the unit. For maximum
performance use rigid duct and a short length of flexible duct
(300mm) for final connections to the unit and the extract valves.