Ink Specifications
Cartridge dimensions
1 (W) x 7.9 (D) x 3.9 (H) inches (25 (W) x 200 (D) x 100 (H) mm)
c
Important:
❏ The ink freezes if left at below 5˚F (-15˚C) for a long time.
If it does freeze, leave it at room temperature
(77˚F (25˚C)) for at least four hours until it has defrosted (without condensation).
❏ Do not disassemble the ink cartridges or refill the ink.
Maintenance Cartridge Specifications
Type Maintenance cartridge for waste ink
Number installed 1
Environmental conditions
In the packaging: -4 to 104˚F (-20 to 40˚C) (temperature), 20 to 85% (humidity)
Installed in printer: Conforms to the general specifications below
Transporting: -4 to 140˚F (-20 to 60˚C ) (temperature) 5 to 85% (humidity) (within one month at
104˚F (40˚C), 120 hours at 140˚F (60˚C)
Cartridge dimensions
3.1 (W) x 10 (D) x 1.5 (H) inches (78.8 (W) x 254.5 (D) x 38.5 (H) mm)
General Specifications
Temperature
Operating: 50 to 95˚F (10 to 35˚C)
Storage (before unpacking): -4 to 140˚F (-20 to 60˚C) (within 120 hours
at 140˚F (60˚C), one
month at 104˚F (40˚C)
Storage (after unpacking): -4 to 104˚F (-20 to 40˚C) (within one month at 104˚F (40 ˚C)
Humidity Operating: 20 to 80% (without condensation)
Storage (before unpacking): 5 to 85% (without condensation)
Storage (after unpacking): 5 to 85% (without condensation)
Weight
Approx. 50.7 pounds (23 kg) (printer only)
Dimensions
18.1 (W) x 16.9 (D) x 13.9 (H) inches (460 (W) x 430 (D) x 354 (H) mm)
See “Necessary space” on page 105
Standards and Approvals
Safety UL 60950-1
CAN/CSA No. 60950-1
Low Voltage Directive 2014/35/EU EN 62368-1
Appendix