3-16 Setup Rev. D
Note:
See the next page for “When the letters are US.”
See “Notes for DIP switch 2-1” (page 3-19) about the DIP SW 2-1 setting.
When you use serial interface model with 1200bps, 2400bps, or 19200bps, you have to adjust DIP switch
“Serial interface selection“ function and Memory switch “Serial communication condition“.
Parallel / USB / Ethernet model (Except serial)
(DIP Switch 1) (DIP Switch 2)
SW Function On Off SW Function On Off
1 Auto line feed Enabled Disabled 1 Print column selection 42/35 40/33
2 Receive buffer
capacity
40 bytes 4 KB 2 Reserved
(Auto cutter enable/
disable)
Type A, B
Fixed to On
Type D
Fixed to Off
3~7 Reserved - Fixed to Off 3~7 Reserved - Fixed to Off
8 BUSY condition Receive
buffer full
Receive
buffer full or
Offline
8 Pin 31 reset signal Used Not used