EasyManuals Logo
Home>eta>Boiler>HACK

eta HACK User Manual

eta HACK
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
42 www.eta.co.at
[Heating circuit] function block Configuration parameter
6.3.3 Screed drying
Settings for screed drying
Set this parameter for each installed heating
circuit.
Detailed descriptions of the parameters are provided
below.
Function [Screed]
For each heating circuit, the function block text menu
contains the necessary settings for the screed drying
program.
With the [Incr. by] and [Incr. every] parameters,
you can set the interval for the incremental
increase in the flow temperature (factory setting 3°C
every 24 hours).
If the maximum temperature [Max. temp.] has been
reached, it is held for a period of [Retain max. temp.].
This is followed by an incremental reduction in tem-
perature. This is configured with the [Set-back by] and
[Set-back every] parameters (factory setting 3 °C
every 24 hours).
Fig. 6-1: Temperature profile of screed drying program
1 [Incr. by]
2 [Incr. every]
3 [Max. temp.]
4 [Retain max. temp.]
Set the start of the drying program with the [Start
screed drying] parameter. If the maximum temperature
is held for the configured duration, the program ends
as soon as the [Flow target] temperature is below the
[Flow] or the current room temperature.
You may change the calculated target
temperature [Flow target] at any time, in order to
commence heating with a higher temperature, for
example.
Heating circuit
Screed
Start screed drying
Flow target
Last change
Incr. by
Incr. every
Max. temp.
Retain max. temp.
Set-back by
Set-back every