EasyManuals Logo
Home>Fagor>DC Drives>DDS RPS-75

Fagor DDS RPS-75 User Manual

Fagor DDS RPS-75
406 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #221 background imageLoading...
Page #221 background image
Selection criteria
5.
Ref.1912
· 221 ·
DDS
HARDWARE
T. H5/14 Selection of the power cabling.
POWER CABLE FOR MAINS CONNECTION
Vmains: Line voltage
AXD/SPD:
400/460 V AC
ACD/SCD:
400/460 V AC
ACD/SCD ... - L
: 200/240 V AC
Rated current through the mains cable
MAINS POWER
COMPACT AXIS DRIVES, ACD:
COMPACT SPINDLE DRIVES, SCD:
Power cable Power cable
In Amperes Model In Amperes Model
C
13.1 MPC-4x1.5 40.0 < C 54.0 MPC-4x16
13,1 < C
17.4
MPC-4x2.5
54.0 < C 70.0
MPC-4x25
17.4 < C
23.0 MPC-4x4 70.0 < C 86.0 MPC-4x35
23.0 < C
30.0
MPC-4x6
86.0 < C 103.0
MPC-4x50
30.0 < C
40.0
MPC-4x10
103.0 < C 130.0
MPC-4x70
The purchase order must indicate the length of the cables.
4
(kW)
· 1000 / (
3 · V
mains
)
=
A
C
Rated current on FXM|FKM servomotors
=
A
C
Max. current on FM7|FM9 motors
=
A
C
Conductor section calculated for the B2 installation method, according to UNE-EN 60204-1:2007.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fagor DDS RPS-75 and is the answer not in the manual?

Fagor DDS RPS-75 Specifications

General IconGeneral
BrandFagor
ModelDDS RPS-75
CategoryDC Drives
LanguageEnglish

Related product manuals