9.5 Paramete r number and descriptio n are liste d in th e fo llowing ta ble.
The manometer is a kind of high pressure equipment, when the heat pump is on, the manometer pointer
2
would point to the pressure value of refrigerant, the max. value of protection is 42kg/Cm . When the heat pump
°
is off, the pointer would point to the same value as actual ambient temperature (e.g. 28 C) and related air
2
pressure (e.g.18kg/ Cm ).
Please check the manometer when you restart the heat pump after not using for a long time, if it shows
ambient temperature valve is smaller than 2 , it means
that refrigerant has leaked a lot, and you need to confirm with professional engineer as soon as possible.
° °
C(When the ambient temp. is higher than 2 C)
Remark:the machine off code(The No. 13, parameter in the previous table):
2:Water tank temp. sensor breakdown
3:Evaporator coil temp. sensor breakdown
4:Discharge temp. sensor breakdown
5:Discharge temp.is too high, thanshop the machine
11:Anti-frozen finishing,than shop the machine
12:High-pressure switch cutting
13:Meet set temp
14:Controller power off
No. 32
19:Water flow switch breakdown
No. Content Scope Default Memorized station
0 The incoming electric memorized sign 0-no effective 1-effective 1 The main board
1 Daily circulation sign 0-no effective 1-effective 1 the wire control panel
2 the setting area X 2℃~10℃,Unit:℃ 3 The main board
3 the setting area Y 0℃~3℃,Unit:℃ 0 The main board
4 The interval for defrosting 15~99,Unit:minute 45 The main board
5 Defrosting-on temperature -9~5℃, Unit:℃ 0 The main board
6 Defrosting-off temperature 5~20℃,Unit:℃ 10 The main board
7
Compressor’s exhaust air protection 90~120℃,Unit:℃ b8: means 118℃ The main board
8 Evaporator coil temperature 1 Unit:℃ Scope:-9℃-80℃ No Setting
9
Discharge gas temperature 1 Unit:℃
98: means 98℃
A8: means 108℃
b8: means 118℃
No Setting
10 ambient temperature Unit:℃ Scope:-9℃-80℃ No Setting
11 Compressor continuous running time Unit:minute Scope:0-99 No Setting
12 Fan continuous running time 1/4 Unit:Second No Setting
13 Compressor auto-off code 1 No Setting
14 On-off imported state Especial:sixteen No Setting
24 Auxiliary heat source 0-no effective 1-effective 0 The main board
25
Water tank temp./water outlet temp.
compensation
-5~5℃, Unit:℃
1
The main board
29 Evaporator coil temperature 2 Unit:℃ Scope:-9℃-80℃ No Setting
32 Compressor auto-off code 2 No Setting
37
Discharge gas temperature 2 Unit:℃
98: means 98℃
A8: means 108℃
b8: means 118℃
No Setting
48 Start ambient temp.(auxiliary heat source) 2~15℃, Unit:℃
7
The main board
20:Defrosting preparation
21:Defrosting finish
22:Error phase or lack of phase with power supply,
then shop the machine
27:Low-pressure switch cutting
22:High-pressure switch cutting during water tank
temp. is high
32:High-pressure switch cutting during dofrosting
Hot Water Series
36