Optional DAS Shock Sensitivity setting Procedure (CM7000, *CM7200)
STEP 1: Turn the ignition to the ‘on’ position
STEP 2: Hold Foot Brake (make sure the CM sees a valid foot brake input)
STEP 3: Tap Lock 3 times from any Firstech remote (including 1Button remotes)
STEP 4: Release Foot Brake *Parking lights will flash 2 times confirming DAS is in programming mode
STEP 5: The CM will chirp/honk/flash (1-10 times) indicating the current sensitivity level
STEP 6: Using any Firstech remote, OEM remote (capable of Controlling the CM900AS through data
module), or the Arm/Disarm analog inputs, tap lock or unlock 1 time to increase or decrease 1
level of sensitivity (up to 10 (least sensitive) or down to 1 (most sensitive)) which should be
confirmed by chirps/horn honks/ flashes
*repeat this process until desired sensitivity level has been reached
a. Example 1. Current sensitivity level is 4, we send 1 lock we should receive 1 chirp or 1
horn honk after 1 second of no incoming commands
b. Example 2. Current level is set at 4, we send lock + lock + lock, after 1 second of
no incoming commands we should receive 3 chirps or horn honks
c. Example 3. Current level is now set at 7, we send unlock + unlock, after 1 second of
no incoming commands we should receive 2 chirps/horn honks/park light flashes
STEP 7: 5 seconds after the last setting change confirmation the CM will chirp/horn honk/flash the
sensitivity level *you will have an additional 5 seconds to make any adjustments
STEP 8: Programming completed.
STEP 9: You are now ready to test the DAS