Feature Option Descriptions
FO = Feature Option
1-01 Unlock before, Lock after:
FO1 - Off
FO2 - On: Sends an unlock command as soon as the remote start sequence is triggered then send a relock
command as soon as the CM7 has confirmed remote start success.
FO3 - Lock after start only: Sends a lock command after the CM7 has confirmed remote start
success.
FO4 - Lock after shutdown only: will send a lock command only after the CM7 has successfully shut
down. Note: It will not provide an output if the CM7 is shut down with an emergency override input.
(i.e. hood pin, or foot brake input)
1-02 Door Lock/Unlock output Pulse Duration: This does not affect the behavior of the factory arm output
(orange wire) or factory alarm disarm output (orange/white wire).
FO1 - 0.8 seconds: (-) Negative lock and unlock output time.
FO2 - 2.5 seconds: (-) Negative lock and unlock output time.
FO3 - 0.125 seconds: (-) Negative lock and unlock output time. This option may be helpful when using
lock/unlock to arm/disarm vehicles that may roll windows down with factory Arm/Disarm wires when
the standard output is too long.
FO4- 3.5 seconds: (-) Negative lock and unlock output time.
1-03 Driver’s Priority Unlock:
FO1 - Off: (default)
FO2 - On: This feature will allow the user to unlock the driver’s door first. If the unlock button is
pressed again within 4 seconds, the other doors will unlock. The driver’s door unlock must be isolated
from the other doors and use the blue (-) unlock. The Orange/Black (-) 2nd unlock (POC setting) is used
to provide unlock output to unlock all other doors.
1-04 Double Pulse Unlock:
FO1 - Off: (default)
FO2 - Unlock: This option will provide a double pulse output only for unlock each time the CM900
executes the unlock command. (Length of output time will be based on feature 1-02 option settings.)
FO3 - Lock: This option will provide a double pulse lock output only for lock each time the CM900
executes the lock command. (Length of output time will be based on feature 1-02 option settings.) FO4
- Lock and unlock: This option will provide a double pulse lock output for both lock and unlock each
time the CM900 executes lock or unlock commands. (Length of output time will be based on feature 1-
02 option settings.)
1-05 Rearm Output:Factory Alarm Arm (FAA) output function options
FO1 - After start, after shutdown, after first lock: This option triggers the FAA after every
successful remote start, every successful remote start shut down, and with every first lock command.
(First lock command is the first arm/lock command sent after the CM900 has been disarmed or
unlocked.)