EasyManuals Logo
Home>Firstech>Remote Starter>CM900AS

Firstech CM900AS User Manual

Firstech CM900AS
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #27 background imageLoading...
Page #27 background image
Alarmand StarterSystem
ww w
.firstechdata.com
CM900
Master
Guide
Copyright 2016 Firstech,
LLC.
Page
27
Feature Option Descriptions
FO = Feature Option
1-01 Unlock before, Lock after:
FO1 - Off
FO2 - On: Sends an unlock command as soon as the remote start sequence is triggered then send a relock
command as soon as the CM7 has confirmed remote start success.
FO3 - Lock after start only: Sends a lock command after the CM7 has confirmed remote start
success.
FO4 - Lock after shutdown only: will send a lock command only after the CM7 has successfully shut
down. Note: It will not provide an output if the CM7 is shut down with an emergency override input.
(i.e. hood pin, or foot brake input)
1-02 Door Lock/Unlock output Pulse Duration: This does not affect the behavior of the factory arm output
(orange wire) or factory alarm disarm output (orange/white wire).
FO1 - 0.8 seconds: (-) Negative lock and unlock output time.
FO2 - 2.5 seconds: (-) Negative lock and unlock output time.
FO3 - 0.125 seconds: (-) Negative lock and unlock output time. This option may be helpful when using
lock/unlock to arm/disarm vehicles that may roll windows down with factory Arm/Disarm wires when
the standard output is too long.
FO4- 3.5 seconds: (-) Negative lock and unlock output time.
1-03 Driver’s Priority Unlock:
FO1 - Off: (default)
FO2 - On: This feature will allow the user to unlock the driver’s door first. If the unlock button is
pressed again within 4 seconds, the other doors will unlock. The driver’s door unlock must be isolated
from the other doors and use the blue (-) unlock. The Orange/Black (-) 2nd unlock (POC setting) is used
to provide unlock output to unlock all other doors.
1-04 Double Pulse Unlock:
FO1 - Off: (default)
FO2 - Unlock: This option will provide a double pulse output only for unlock each time the CM900
executes the unlock command. (Length of output time will be based on feature 1-02 option settings.)
FO3 - Lock: This option will provide a double pulse lock output only for lock each time the CM900
executes the lock command. (Length of output time will be based on feature 1-02 option settings.) FO4
- Lock and unlock: This option will provide a double pulse lock output for both lock and unlock each
time the CM900 executes lock or unlock commands. (Length of output time will be based on feature 1-
02 option settings.)
1-05 Rearm Output:Factory Alarm Arm (FAA) output function options
FO1 - After start, after shutdown, after first lock: This option triggers the FAA after every
successful remote start, every successful remote start shut down, and with every first lock command.
(First lock command is the first arm/lock command sent after the CM900 has been disarmed or
unlocked.)