EasyManuals Logo
Home>Firstech>Remote Starter>CM900AS

Firstech CM900AS User Manual

Firstech CM900AS
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
Alarmand StarterSystem
ww w
.firstechdata.com
CM900
Master
Guide
Copyright 2016 Firstech,
LLC.
Page
42
SO4- Cold Start Temperature: (Feature 2-08 must first be set to option 4.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be set
between -30 ~ 0 [°C] / -22 ~ 32 [°F] with a default temperature of -15°C / 5°F default for the Cold Start
Timer mode activation
SO5- Hot Start Temperature: (Feature 2-09 must first be set to option 4.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be set
between 20°C ~ 40°C / 68°F ~ 104°F with a default temperature of 40°C / 104°F default the Hot Start
Timer Mode activation
SO6- Defrost Temperature: (Feature 3-13 must first be set to option 3.) This special option allows a
specific temperature (in degrees F or degrees C based on OP500 software update v.30 V1 or V2) to be set
between 0°C/32°F ~ 13°C/55°F with a default temperature of 6°C/42°F for the defrost activation
Special Option Group 2
This special option group allows you to determine the output type of the POC wire you’re using. For example,
if you want to set POC #5 (default setting status out with setting value of 0) to Aux 1, you will need change
special option 5 to setting value 10. This must be done with the OP500.
POC 1 - Green/White • Parking Light Output: (default setting value 0) This channel will provide a
250mA (-) negative output when the CM900 parking lights output is generated (function also
POC setting 1)
POC 2 - Blue/Green • Lock: (default setting value 0) This channel will provide a 250mA output with
the lock/arm command. (function also POC setting 25)
POC 3 - Blue • Unlock: (default setting 0) This channel will provide a 250mA output with the
unlock/disarm command. (function also POC setting 26)
POC 4 - Black • GWR (ground when running aka status output): (default setting value 0) This channel
will provide a 250mA output with the remote start activation command and continue to provide
output until 100mS after the remote start process has shut own. (function also POC setting 5)
POC 5 - Orange • FAA (Factory Alarm Arm): (default setting value 0) This channel will provide a
250mA output with the lock/arm command. Note: the CM900 will provide this output approx.
100mS before the unlock output. (function also POC setting 6)
POC 6 - Orange/White • FAD (Factory Alarm Disarm): (default setting value 0) This channel will
provide a 250mA output with the unlock/disarm command. Note: the CM900 will provide this
output approx. 100mS before the unlock output. (function also POC setting 7)
POC 7 - White • Horn: (default setting) This channel will provide a 250mA output when Horn is triggered.
(function also POC setting 8)
POC setting value description (SV)
SV 0 DEFAULT SETTING by wire
SV 1 - Parking light: provides a 250mA (-) negative parking light output on any POC programmed with
this setting.
SV 2 - Starter: provides a 250mA (-) negative starter output on any POC programmed with this
setting.
SV 3 - Ignition: provides a 250mA (-) negative ignition output on any POC programmed with this
setting.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Firstech CM900AS and is the answer not in the manual?

Firstech CM900AS Specifications

General IconGeneral
BrandFirstech
ModelCM900AS
CategoryRemote Starter
LanguageEnglish

Related product manuals