EasyManuals Logo

Fujitsu AOU18RLXFZ User Manual

Fujitsu AOU18RLXFZ
319 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #108 background imageLoading...
Page #108 background image
11-2. External output
Use an external output cable with appropriate external dimension, depending on the number of ca-
bles to be installed.
¢
Operation status output
Indoor unit type Connector
Compact cassette CN103
Slim duct CN103
Wall mounted
ASU7RLF1, ASU9RLF1, ASU12RLF1, ASU15RLF1 CNB01
ASU9RLS2, ASU12RLS2, ASU15RLS2 CNB01
ASU7RLF, ASU9RLF, ASU12RLF CN304
ASU18RLF, ASU24RLF CN16
Floor AGU9RLF, AGU12RLF, AGU15RLF CN20
Air conditioner operation status signal can be output.
Circuit diagram example
Locally purchased
Indoor unit
control PCB
*1
Connected unit
Example: Display
Example: Relay unit
Relay
power supply
DC 24 V
1
2
Signal
V
Connector
33 ft
(10 m)*2
*1: PCB of communication kit is used for wall mounted type (ASU7RLF1, ASU9RLF1,
ASU12RLF1, and ASU15RLF1).
*2: Make the distance from the PCB to the connected unit within 33 ft (10 m).
Relay spec: Max. DC 24 V, 10 mA to less than 500 mA.
On
Off
Operation
Stop
Indoor unit
Output signal
- 100 -
11-2. External output 11. External input and output
MULTI TYPE
2, 3, 4 ROOMS TYPE
MULTI TYPE
2, 3, 4 ROOMS TYPE

Table of Contents

Other manuals for Fujitsu AOU18RLXFZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU18RLXFZ and is the answer not in the manual?

Fujitsu AOU18RLXFZ Specifications

General IconGeneral
BrandFujitsu
ModelAOU18RLXFZ
CategoryAir Conditioner
LanguageEnglish

Related product manuals