EasyManuals Logo
Home>Fujitsu>Air Conditioner>AOU18RLXFZ

Fujitsu AOU18RLXFZ User Manual

Fujitsu AOU18RLXFZ
319 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #315 background imageLoading...
Page #315 background image
12. Safety devices
Type of protection Protection form
Model
AOU36RLXFZ1
Circuit protection
Current fuse
(Main PCB)
250 V, 5 A
250 V, 3.15 A
Current fuse
(Near the terminal)
250 V, 10 A
Fan motor protection Temperature thermistor
Activate
251 ±16 °F
(122 ±9 °C)
Fan motor stop
Reset
240
+18
-16
°F
(116
+10
-9
°C)
Fan motor restart
Compressor protection
Temperature thermistor
Activate
226 ±4 °F
(108 ±2 °C)
Compressor stop
Reset
176 ±4 °F
(80 ±2 °C)
Compressor restart
Thermal protection program
(Outdoor temp.)*
Activate
-15 °C
Compressor stop
Reset
Refrigerant circuit
protection
Pressure switch 1
Activate
609 ±15 PSI
(4.2 ±0.1 MPa)
Reset
464 ±22 PSI
(3.2 ±0.15 MPa)
Pressure switch 2: For control device. (Refer to the wiring diagram.)
*: Only for cooling or dry operation.
- 307 -
12. Safety devices
OUTDOOR UNIT
AOU36RLXFZ1
OUTDOOR UNIT
AOU36RLXFZ1

Table of Contents

Other manuals for Fujitsu AOU18RLXFZ

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOU18RLXFZ and is the answer not in the manual?

Fujitsu AOU18RLXFZ Specifications

General IconGeneral
BrandFujitsu
ModelAOU18RLXFZ
CategoryAir Conditioner
LanguageEnglish