1-2. Error code table (Outdoor unit: for 36/45 model only)
The operation status is determined by the lighting up and blinking of the LED lamp.
After check that ERROR LED lamp blinks, press the ENTER button once.
NOTE: For the positions of LED lamp and buttons, refer to "Functionsettings (for outdoor unit)" in
Chapter 5. FIELD →ORK.
Error contents
POWER/
MODE
ERROR
PUMP
DOWN
LOW NOISE PEAK CUT
L1 L2 L3 L4 L5 L6
E: 11. Serial communication error
(Serial forward transfer error) (Indoor
unit)
2
1
1
E: 11. Serial communication error
(Serial forward transfer error) (Indoor
unit)
2
1
1
E: 12. →ired remote controller
communication error (Indoor unit)
2
5
15
E: 15. Automatic air flow adjustment
error (Indoor unit)
2
5
15
E: 18. External communication error
(Indoor unit)
2
5
15
E: 23. Combination error (Outdoor unit)
2
5
15
E: 32. Indoor unit main PCB error
(Indoor unit)
2
5
15
E: 33. Indoor unit motor electricity
consumption detection error (Indoor
unit)
2
5
15
E: 35. MANUAL AUTO button error
(Indoor unit)
2
5
15
E: 39. Indoor unit power supply error for
fan motor (Indoor unit)
2
5
15
E: 3A. Indoor unit communication circuit
(wired remote controller) error
2
5
15
E: 41. Room temperature sensor error
(Indoor unit)
2
5
15
E: 42. Indoor unit heat exchanger
sensor error (Indoor unit)
2
5
15
E: 51. Indoor unit fan motor error
(Indoor unit)
2
5
15
E: 53. Drain pump error (Indoor unit)
2
5
15
E: 62. Outdoor unit main PCB error
(Outdoor unit)
2
6
2
E: 63. Inverter error (Outdoor unit)
2
6
3
E: 65. Trip terminal L error (Outdoor
unit)
2
6
5
E: 71. Discharge thermistor error
(Outdoor unit)
2
7
1
E: 72. Compressor thermistor error
(Outdoor unit)
2
7
2
E: 73. Heat exchanger (Middle/Outlet)
temperature thermistor error (Outdoor
unit)
2
7
3
E: 74. Outdoor temperature thermistor
error (Outdoor unit)
2
7
4
E: 77. Heat sink thermistor error
(Outdoor unit)
2
7
7
1-2. Error code table (Outdoor unit: for 36/45 model only) - (03-2) - 1. Error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu ARXG36KMLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG36KMLA and is the answer not in the manual?

Fujitsu ARXG36KMLA Specifications

General IconGeneral
BrandFujitsu
ModelARXG36KMLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals