2-15. E: 53. Drain pump error (Indoor unit)
Indicator
→ired remote
controller
Error code E: 53
Detective actuator
Indoor unit main PCB
→hen Float switch is ON for more than 3 minutes.
Float switch
Forecast of cause
Float switch failure
Shorted connector/wire failure
Main PCB failure
Drain pump failure
Hose clogging
Check point 1. Check float switch
Check operation of float switch. (any blocking by dust, etc.)
Remove float switch and check ON/OFF switching operation by using a meter.
-> If float switch is abnormal, replace it.
Check point 2. Check connector and wire
Check loose contact of CN9 and shorted wire (pinched wire).
-> Replace float switch if the wire is abnormal
Check point 3. Check drain hose
Check drain hose.
-> If there is hose clogging. Please clear the clog.
Check point 4. Replace drain pump
If check point 1 to 3 do not improve the symptom, replace drain pump.
Check point 5. Replace main PCB
If check point 4 do not improve the symptom, replace main PCB.
End
2-15. E: 53. Drain pump error (Indoor unit) - (03-20) - 2. Troubleshooting with error code
TROUBLESHOOTING
TROUBLESHOOTING

Table of Contents

Other manuals for Fujitsu ARXG36KMLA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ARXG36KMLA and is the answer not in the manual?

Fujitsu ARXG36KMLA Specifications

General IconGeneral
BrandFujitsu
ModelARXG36KMLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals