(Fig.1:LimitofMaximum Frequency based on Outdoor Temperature )
1. COOLING OPERATION
1-1 COOLING CAPACITY CONTROL
A sensor (room temperature thermistor) built in the indoor unit body will usually perceive
difference or variation between a set temperature and present room temperature, and
controls the operation frequency of the compressor.
* If the room temperature is 2°C higher than a set temperature, the compressor operation
frequency will attain to maximum performance.
minimum
frequency
maximum
frequency
maximum
frequency
ASYA07LCC 18Hz 61Hz 80Hz
ASYA09LCC 18Hz 61Hz 80Hz
ASYA12LCC 18Hz 80Hz 96Hz
Outside air Outside air
temperature temperature
36°C
Azone
34°C
32°C
B zone
30°C
21°C
C zone
19°C
D zone
Hi Me Lo Quiet
A zone 80Hz 61Hz 51Hz 33Hz
B zone 80Hz 61Hz 51Hz 33Hz
C zone 80Hz 61Hz 51Hz 33Hz
07LCC
09LCC
D zone 51Hz 42Hz 36Hz 21Hz
E zone 51Hz 42Hz 36Hz 21Hz
F zone 51Hz 42Hz 36Hz 21Hz
A zone 96Hz 61Hz 51Hz 33Hz12LCC
B zone 96Hz 61Hz 51Hz 33Hz
C zone 96Hz 61Hz 51Hz 33Hz
D zone 51Hz 42Hz 36Hz 22Hz
E zone 51Hz 42Hz 36Hz 22Hz
09LDC
F zone 51Hz 42Hz 36Hz 22Hz
Azone
B zone
C zone
D zone
Ezone
F zone
( Table1:Compressor Frequency Range )
When the compressor operates for 30 minutes continuously at over the maximum frequency ,
the maximum frequency is changed from Maximum Frequency to Maximum Frequency .
The room temperature is controlled 1°C lower than the setting temperature for 40 minutes
after starting the operation.
After 40 minutes, it is controlled based on the normal setting temperature.
05-01
E zone
F zone
10°C
0°C
12°C
2°C
80Hz 61Hz 51Hz 33Hz
80Hz 61Hz 51Hz 33Hz
80Hz 61Hz 51Hz 33Hz
51Hz 42Hz 36Hz 27Hz
51Hz 42Hz 36Hz 27Hz
51Hz 42Hz 36Hz 27Hz
ASYB09LDC 18Hz 61Hz 80Hz
ASYB12LDC 18Hz 80Hz 96Hz
ASYA14LCC 18Hz 70Hz 90Hz
ASYA18LCC 18Hz 70Hz 90Hz
12LDC A zone
B zone
C zone
D zone
Ezone
F zone
96Hz 61Hz 51Hz 33Hz
96Hz 61Hz 51Hz 33Hz
96Hz 61Hz 51Hz 33Hz
57Hz 42Hz 36Hz 27Hz
57Hz 42Hz 36Hz 27Hz
57Hz 42Hz 36Hz 27Hz
14LCC
18LCC
Azone
B zone
C zone
D zone
Ezone
F zone
90Hz 45Hz 42Hz 30Hz
90Hz 45Hz 42Hz 30Hz
90Hz 45Hz 42Hz 30Hz
58Hz 38Hz 34Hz 24Hz
58Hz 38Hz 34Hz 24Hz
58Hz 38Hz 34Hz 24Hz
* When the room temperature is between +2°C to -2.5°C of the setting temperature,
the compressor frequency is controlled within the range shown in Table1.
However, the maximum frequency is limited in the range shown in Figure 1 based on the
fan speed mode and the outdoor temperature.
* If the room temperature is 2.5°C lower than a set temperature, the compressor will be
stopped.

Other manuals for Fujitsu ASYB12LDC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASYB12LDC and is the answer not in the manual?

Fujitsu ASYB12LDC Specifications

General IconGeneral
BrandFujitsu
ModelASYB12LDC
CategoryAir Conditioner
LanguageEnglish

Related product manuals