5. INDOOR FAN CONTROL
(1).Fan speed
( Table 5 : Indoor Fan Speed )
07/09LCC, 09LDC
Operat ion mode Air flow mode Speed (rpm)
Hi 1390
Me+ 1350
M e 1200
Lo 1000
Quiet 760
Cool air
prevention
760
Heating
S-Lo 480
Hi 1300
Me 1120
Lo 950
Cooling
Fan
Quiet 700
Dry 700
(2).FAN OPERATION
The airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH, while the indoor
fan only runs.
When Fan mode is set at (Auto), it operates on (MED) Fan Speed.
12LCC, 12LDC
Operation mode Air flow mode Speed (rpm)
Hi 14 40
Me+ 1350
M e 1200
Lo 1000
Quiet 760
Cool air
prevention
760
Heating
S-Lo 480
Hi 1370
Me 1150
Lo 950
Cooling
Fan
Quiet 700
Dry 700
05-05
14/18LCC
Operation mode Air flow mode Speed (rpm)
Hi 1480
Me+ 1420
M e 1300
Lo 1110
Quiet 950
Cool air
prevention
850
Heating
S-Lo 480
Hi 1480
M e 1260
Lo 1040
Cooling
Fan
Quiet 850
Dry 850