1-3. Dry operation
The rotation number of compressor shall change according to the temperature, set temperature, and
room temperature variation which the room temperature sensor of the indoor unit has detected as
shown in the table below.
Zone is defined by set temperature and room temperature.
Rotation number range of compressor
Unit: rps
Model name Outdoor temperature zone Operating rotation number
ASYG07KMCF
ASYG09KMCF
ASYG12KMCF
X zone 24
J zone 18
Y zone 0
ASYG14KMCF
X zone 24
J zone 16
Y zone 0
Compressor control based on room temperature
Ts+0.5°C
Ts -1.5°C
Ts-0.5°C
Ts+1.5°C
X zone
J zone
Y zone
Room temperature drops
Room temperature rises
Ts: Set temperature