2-4. Details of control input function
¢
Operation/Stop mode 1
• In the case of "Edge" input
Function
setting
External Input and
Output PCB
External input Input signal Command
Rotary
switch
SW302
46-00
— Input of indoor unit CN46
Off → On Operation
On → Off Stop
1 Edge
External Input and
Output PCB
CN313
Off → On Operation
On → Off Stop
On
Off
Remote controller
On
Off
Indoor unit operation
On
CN313
• In the case of "Pulse" input
Function
setting
External Input and
Output PCB
External input Input signal Command
Rotary
switch
SW302
46-00 1 Pulse
External Input and
Output PCB
CN313
Pulse
Operation
CN314 Stop
On
On
Off
On
Off
Remote controller
On
Off
Indoor unit operation
CN313
CN314
NOTES:
• The last command has priority.
• The indoor units within the same remote controller group operates in the same mode.
2-4. Details of control input function
- (05-16) - 2. External input and output