1-5. Rotation number of compressor limitation by outdoor
temperature
The minimum rotation number of compressor is limited by outdoor temperature as below.
• Cooling/Dry mode
E zone
38°C
D zone
°C
C zone
B zone
A zone
12
18
°C
7°C
Unit: rps
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOHG30KBTA4
AOHG36KBTA5
A zone 20
B zone 18
C zone 13
D zone 10
E zone 20
• Heating mode
D zone
5°C
C zone
B zone
A zone
-1°C
-6°C
Unit: rps
Model name Outdoor temperature zone
Limitation of compressor
rotation number
AOHG30KBTA4
AOHG36KBTA5
A zone 30
B zone 25
C zone 15
D zone 10
1-5. Rotation number of compressor limitation by outdoor temperature - (04-17) - 1. Rotation number control of compressor