11. Safety devices
Type of
protection
Protection form
Model
AOHG36KRTA
Circuit
protection
Current fuse
(Main PCB)
250 V, 30 A × 2
250 V, 10 A × 2
Fan motor
protection
Thermal protection program
Activate
122 ±9 °C
Fan motor stop
Reset
116
+10
-9
°C
Fan motor restart
Compressor
protection
Thermal protection program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Compressor temp.)
Activate
108 °C
Compressor stop
Reset
80 °C or less
Compressor restart
Thermal protection program
(Outdoor temp.)
Activate
-20 °C
Compressor stop
Reset
-15 °C
Compressor restart
Type of
protection
Protection form
Model
AOHG45KRTA
AOHG54KRTA
Circuit
protection
Current fuse
(Main PCB)
250 V, 30 A × 2
250 V, 10 A × 2
Fan motor
protection
Thermal protection program
Activate
150 ±15 °C
Fan motor stop
Reset
120 ±15°C
Fan motor restart
Compressor
protection
Thermal protection program
(Discharge temp.)
Activate
110 °C
Compressor stop
Reset
After 7 minutes
Compressor restart
Thermal protection program
(Compressor temp.)
Activate
108 °C
Compressor stop
Reset
80 °C or less
Compressor restart
Thermal protection program
(Outdoor temp.)
Activate
-20 °C
Compressor stop
Reset
-15 °C
Compressor restart
- 60 -
11. Safety devices
OUTDOOR UNIT
AOHG36-54KRTA
OUTDOOR UNIT
AOHG36-54KRTA

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu General ARXG36KHTAP and is the answer not in the manual?

Fujitsu General ARXG36KHTAP Specifications

General IconGeneral
BrandFujitsu
ModelGeneral ARXG36KHTAP
CategoryAir Conditioner
LanguageEnglish

Related product manuals