50 Upgrade and Maintenance Manual RX1330 M3
Basic hardware procedures
4.1.1 Locating the defective server
When working in a datacenter environment, switch on the ID indicator on the
front and rear connector panels of the server for easy identification.
Ê Press the ID button on the front panel, use the iRMC web frontend or the
ServerView Operation Manager user interface to switch on the system
identification LEDs.
I For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual and the "Integrated Remote Management
Controller" user guide.
Ê When using ServerView Operations Manager to toggle the ID indicator,
choose Single System View and press the Locate button.
Ê Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
4.1.2 Determining the error class
The Local Service Concept (LSC) allows you to identify defective server
components. Failure events are assigned to one of two error classes:
– Global Error events that need to be resolved by maintenance personnel
– Customer Self Service (CSS) error events that may be resolved by
operating personnel
Global Error and CSS LEDs indicate, if the defective component is a customer
replaceable unit or if maintenance personnel needs to be dispatched to replace
the part.
I The indicators also light up in standby mode and after a server restart
due to a power failure.
4.1.2.1 Global Error indicator
Ê Check the Global Error indicator on the front panel of the server.
Ê For further diagnostics, proceed as follows:
– Hardware errors:
Check the System Event Log (SEL) as described in section "Viewing the
SEL" on page 92.