EasyManuals Logo
Home>Fujitsu>Server>PRIMERGY RX2510 M2

Fujitsu PRIMERGY RX2510 M2 User Manual

Fujitsu PRIMERGY RX2510 M2
74 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #73 background imageLoading...
Page #73 background image
RX2510 M2 Operating Manual 73
Troubleshooting and tips
8.9 Added drive reported as defective
RAID controller is not configured for this drive
The drive was probably installed when the system was switched off.
Ê Reconfigure the RAID controller for the drive using the corresponding utility.
Information is provided in the documentation for the RAID controller.
or
Ê Remove and reinstall the drive while the system is switched ON.
If the drive continues to be shown as defective, then replace it.
8.10 Error message on screen
The meaning of the error message is explained in the documentation for the
relevant components and programs on the Fujitsu manuals server.
8.11 Expansion cards or onboard devices not
recognized
When an expansion card is added, other expansion cards or onboard devices
might not be recognized.
Ê Reinstall the drivers for the expansion cards or onboard devices that are not
recognized.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2510 M2 and is the answer not in the manual?

Fujitsu PRIMERGY RX2510 M2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2510 M2
CategoryServer
LanguageEnglish

Related product manuals