74 Operating Manual RX2510 M2
Troubleshooting and tips
8.12 Temperature warning
A temperature warning is output to the hardware event log and OS event log, or
ServerView issues a notification of a temperature warning such as by a popup
message.
The above log is output or the above notification is issued by ServerView when
the ambient temperature exceeds the upper limit of the temperature
boundaries. The upper limit is 35°C for standard server and 40°C or 45°C with
Fujitsu Advanced Thermal design.
Ê Although continued use within the temperature boundaries poses no
problems within itself, reconsider the surrounding environment conditions if
this log is output or if ServerView issues this notification.
8.13 No effect of keyboard or mouse
Typing the keyboard does not display any characters, or the mouse cursor does
not move.
Ê Check to see whether the keyboard and mouse are connected properly. If
they are not connected or you replaced them yourself, then connect the
cables to the server.
8.14 Optical drive cannot read data
Ê Check to see whether the CD/DVD/BD is inserted properly. If the
CD/DVD/BD is not inserted, correctly insert the disk so that the label is
facing up.
Ê Check to see whether the CD/DVD/BD is not dirty. If the CD/DVD/BD is dirty,
wipe it in a radial way with a soft, dry cloth.
Ê Check to see whether the CD/DVD/BD is not scratched or bent. If scratched
or damaged, replace the CD/DVD/BD.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX2510 M2 and is the answer not in the manual?

Fujitsu PRIMERGY RX2510 M2 Specifications

General IconGeneral
BrandFujitsu
ModelPRIMERGY RX2510 M2
CategoryServer
LanguageEnglish

Related product manuals