62 Operating Manual
TX1330 M2
Starting up and operation
6.2.1.2 Indicators on the control panel
Pos. Indicator Status Description
4 ID indicator
blue on
server has been highlighted using
ServerView Operations Manager, iRMC
web frontend or the ID button on the
front panel for easy identification
blue
flashing
server has been highlighted using IRMC
(AVR) when local VGA off for easy
identification
5 CSS indicator
off no critical event (CSS component)
orange on prefailure detected (CSS component)
orange
flashing
CSS component failure
6
Global error
indicator
off no critical event (non CSS component)
orange on
prefailure detected (non CSS
component)
orange
flashing
non CSS component failure
7
HDD activity
indicator
green
flashing
data access in progress
8
Power-on
indicator
off
is off in the following case:
– the system is in power-off mode but
connected to the mains (AC
connected)
green on
is on in the following cases:
– the system has been switched on
and is in power-on delay
– the system is powered on and in
normal operation (S0)
flashes
slowly (1/2
Hz)
iRMC S4 is not ready