APPENDIX 2 ALERT ICONS, IDS, MEANINGS AND MEASURES
AP-4
AlertI/F1(2) mode alerts, IDs, meanings and measures
ID Indication Priority Category Meaning Measures
250*
1
Warning
Warning
Warning
Alarm
Alarm
Alarm
Caution
B
B
B
A
A
A
B
COM ERR with
Processor Unit
DC Power
Failure
AC Power
Failure
BNWAS Alarm
is 1st Stage
BNWAS Alarm
is 2nd Stage
BNWAS Alarm
is 3rd Stage
Communication
error with BAM
(220)001*
2
(220)002*
2
220003*
3
220004*
3
220005*
3
220950*
3
Communication failure
between Processor Unit
and Main Alarm Panel
DC power to the unit is
interrupted or stopped.
Check power to the
unit, check cabling
and connections to
the unit.
Check power to the
unit, check cabling
and connections to
the unit.
Press any key on the
Main Alarm Panel, or
press the Timer
Reset Panel button.
Press the RESET
key on the Main
Alarm Panel.
AC power to the unit is
interrupted or stopped.
Watch alarm is at first
stage
Watch alarm is at
second stage
Press the RESET
key on the Main
Alarm Panel.
Watch alarm is at third
stage
Communication failure
between Processor Unit
and Bridge Alert
Management (BAM)
system
Check connection with
BAM system. Contact
FURUNO if the problem
is not resolved.
Consult a FURUNO
technician.
*
1
: This alert is displayed in three-digit format, regardless of selected alert mode.
*
2
: These alerts’ ID is displayed in three-digit format for AlertI/F1 mode, six-digit
format for AlertI/F2 mode.
EG: 001 - Alert I/F1 mode
220001 - AlertI/F2 mode
*
3
: These alerts are displayed only when AlertI/F2 mode is active.