4. INSTALLATION
4-13
4.7.2 Wiring information
Item Description
Operator fitness FAR-2105: It is not possible to create a connection for operator fitness
between FAR-2105 and the Processor Unit, because the FAR-2105
does not have operator fitness output.
FAR-2107: Use port J612 (#7/8 for operator fitness), where a contact
signal is available.
Other makes of radars: Check for availability of contact signal.
FRU12-05AFFM
(between BR-510 and
BR-520)
This cable is fit with a Micro-C connector (male) on one end and a stripped
end for connection to the BR-520. The standard length is 6 m. 10 m, 20 m,
30 m, 40 m, and 50 m cables are optionally available.
Cable MPYC-7
(between BR-530/550
and BR-520)
40 m and the total length for all units is max. 150 m. For example, when
four BR-530 are installed: No.1 BR-530: 40 m No. 2 BR-530: 40 m No. 3
BR-530: 40 m No. 4 BR-530: 30 m Total length: 150 m
Motion Detector
BR-560
• Pyroelectric detection
Detection range: Up to 5m, 80°×80°
Detection rate: 0.8 thru 1.2 m/s
• Detection sensitivity: 4°C (difference from surround in temperature)
Generally, up to two Motion Detectors can be installed, at INPUT3/4 and
INPUT5-8. Also, INPUT port 2 can be used by setting [INPUT2] on the Ser-
vice menu to [Timer Reset].
INPUT2 (TB17) Backup Navigator signal or Timer Reset signal (operator fitness, motion
detector) can be connected to the INPUT Port 2. Select the signal from the
Service menu. When the Backup navigator mode is used, set the external
equipment's output signals as follows: Power off: CLOSE, Normal working:
CLOSE, Alarm generated: OPEN
506
10 10
Connect cores
to WAGO terminal block.
Vinyl tape
Set this part
in cable clamp.
SIgnal cable FRU12-05AFFM (Main Alarm Panel)
80 mm 80 mm
Fix cables to post with cable tie
Wrap wires with
vinyl tape.
Wrap armor with
vinyl tape.
How to fabricate cables for processor unit

Table of Contents

Other manuals for Furuno BR-500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno BR-500 and is the answer not in the manual?

Furuno BR-500 Specifications

General IconGeneral
BrandFuruno
ModelBR-500
CategorySecurity System
LanguageEnglish

Related product manuals