EasyManuals Logo
Home>Furuno>GPS>GP-150

Furuno GP-150 User Manual

Furuno GP-150
99 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #54 background imageLoading...
Page #54 background image
. MENU SETTIN S
-
Enlarging characters
The si e of the indications of position or user
defined display areas can be enlarged on the
Data display.
1) On the Data display, with no enlarged
characters, press the CSO ONO
key to turn on the oom icon.
2) Operate the cursor keys to select data to
enlarge in the window.
3) Press the OOM IN key.
To switch character si e from enlarged to
normal, press the OOM O T key at step 3.
SEP 12, 2003 23:59'59" U
N12°
E123°
POSITION
23.456'
23.456'
SEP 12, 2003 23:59'59" U
12° 23.456' N
123° 23.456' E
POSITION
RNG
31.23
nm
SOG
12.3
kt
BRG
223.4°
COG
123.4°
TO : 001
MARINE
POINT1
NEXT
: 002
MARINE
POINT2
ZOOM
IN
ZOOM
OUT
Position
User-defined
display window
W84
W84
D3D 100m
SAFE
D3D 100m
SAFE
Zoom icon
Figure 8-7 How to enlarge indications on the
data display
.4 Settings or Connection
o Na igator
Besides its fundamental function of
displaying position, the P-1 0 can also
output various data to external equipment.
Before outputting data to external equipment,
first determine what data the external
equipment requires. Output only necessary
data to ensure data will be output correctly.
All data transmitted by marine electronics
equipment are prefixed with a two character
code called a talker. The same talker must
be shared by the transmitting and receiving
equipment to transmit and receive data
successfully. The P-1 0 transmits data
using the P ( PS talker), however it can
also transmit using the oran ( C) or Decca
(DE) talker.
Because the P talker is a relatively new
system some early model equipment may
not recogni e this talker.
DATA 1 output setting
1) Press MEN ESC, and 3. The DATA 1,
3 OUTPUT SETUP menu appears.
Talker ID P C DE
Output Data (00- 0 sec)
1. AAM:00 APA:00 APB:04 BOD:00
2. BWR:00 BWW:00 A:00 :01
3. RMB:01 RMC:00 T :01 WC :00
4. DR:00 WP :00 TE:00 DA:01
. NS:00 BS:01 Rnn:00 RTE:00
DATA3. og Pulse 400ppm
DATA 1, 3 OUTPUT SETUP
MENU : Escape
ENT : Enter
Settings shown here are default settings.
This line appears only when O is
selected by internal jumper wires.
Data Fmt. 1. 2.0 IEC
200ppm
Figure 8-8 DATA 1, 3 OUTPUT
SETUP menu
2) Press
or to select Data Fmt.

Table of Contents

Other manuals for Furuno GP-150

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno GP-150 and is the answer not in the manual?

Furuno GP-150 Specifications

General IconGeneral
BrandFuruno
ModelGP-150
CategoryGPS
LanguageEnglish

Related product manuals