EasyManuals Logo
Home>GE>Heat Pump>ASYW18CRDWA

GE ASYW18CRDWA User Manual

GE ASYW18CRDWA
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
ENGLISH
System
ET42ET81ET21ET90metsyS
Outdoor 1U09TE1VHA 1U12TE1VHA 1U18TE2VHA 1U24TE2VHA
Indoor
AW09TE1VHA AW12TE1VH
A
AW18TE2VHA AW24TE2VHA
Rated Capacity Btu/hr 000,42000,81000,21000,9
Capacity Range Btu/hr 3,800~12,000 4,100~12,500 5,000~19,000 6,500~26,000
Rated Power Input W 051,2056,1002,1018
61616161REES
0.010.010.110.11REE
Moisture Removal Pt./h 09.502.404.305.2
R
ated Heating Capacity 47°F
B
tu/h
r
000,62000,91000,21000,01
Heating Capacity Range Btu/hr 4,100~12,000 4,500~16,000 5,400~22,000 6,800~28,000
Rated Power Input W 004,2007,1000,1058
0.90.90.90.9FPSH
R
ated Heating Capacity 17°F
B
tu/h
r
006,61002,11008,7006,5
M
ax. Heating Capacity 17°F
B
tu/h
r
003,91005,51000,01002,8
Heating Capacity 5°F Btu/hr 005,51004,21000,8006,6
Heating Capacity -4°F Btu/hr 009,21005,9002,6001,5
Cooling °F(°C)
14°F~115°F(-10~46
) 14°F~115°F(-10~46 )
0°F~115°F(-18~46
) 0°F~115°F(-18~46 )
Heating °F(°C) -4°F~75°F
-20-24 -4°F~75°F -20-24 -4°F~75°F -20-24 -4°F~75°F -20-24
Power Suppl
y
Voltage, Cycle, Phase V/Hz/- 115/60/1 115/60/1 208-230/60/1 208-230/60/1
Compressor Type
Maximum Fuse Size A 52020202
Minimum Circuit Amp A 91718181
Outdoor Fan Speed RPM 008008058058
DC Inverter Driven Rotary
Model Name
Cooling
Operating
Range
Heating
Outdoor Noise Level dB 35650574
Dimension: Height in (mm)
21 1/4(540) 21 1/4(540) 27 7/16 (697) 30 (762)
Dimension: Width in (mm)
30 11/16(780) 30 11/16(780) 35 (890) 36 3/16 (920)
Dimension: Depth in (mm)
9 5/8(245) 9 5/8(245) 13 7/8 (353) 15 1/8 (385)
Weight (Ship/Net)- lbs (kg) 66.2/58.4(30/26.5) 71.7/63.9(32.5/29) 105.8/97.0(48.0/44.0) 121.3/112.5(55.0/51.0)
Fan Speed Stages 5 + Auto 5 + Auto 5 + Auto 5 + Auto
Airflow
(Turbo/High/Med/Low/Quiet) CFM
305/295/280/265/240 310/300/287/275/245 545/530/505/475/460 665/650/610/570/555
Motor Speed
(Turbo/High/Med/Low/Quiet) RPM
1150/1050/950/850/750 1200/1100/1000/900/800 1150/1100/1000/900/850 1250/1200/1050/900/850
Indoor Sound Level dB
(Turbo/High/Med/Low/Quiet)
43-7433-5432-9332-93
Dimension: Height in (mm)
11 7/16(290) 11 7/16(290)
12 1/2(318) 13 3/16(335)
Dimension: Width in (mm)
34(864) 34(864)
39 11/16(1008) 44 5/16(1125)
Dimension: Depth in (mm)
7 7/8(200) 7 7/8(200)
8 7/8(225) 9 7/16(240)
Weight (Ship/Net)- lbs (kg) 24.7/19.9(11.2/9.0) 24.7/19.9(11.2/9.0) 33.1/26.5(15.0/12.0) 38.6/30.9(17.5/14.0)
eralFeralFeralFeralFsnoitcennoC
Liquid O.D. in 4/14/14/14/1
Suction O.D. in 2/12/18/38/3
Factory Charge Oz 0.766.043.535.62
Maximum Line Length Ft / m 52/3852/3802/6602/66
Maximum Height Ft / m 51/0551/0501/3301/33
Refrigerat
Lines
Outdoor Unit
Indoor Unit
INSTALLATION PAGE 25