4
Specification guidelines.
About the reverse osmosis system.
What the Reverse Osmosis System Does
The system makes a good supply of drinking water each day.
How much it will make depends primarily on these things…
Product – height 16 width 17 depth 6
Reverse Osmosis removes Total Dissolved Solids (TDS) and organic matter from water by diffusing it
through a special membrane. The membrane separates minerals and impurities from the water and they
are flushed to the drain. High quality product water goes directly to the drinking water faucet or to the
storage tank. The system makes a good supply of drinking water each day see
Specification Guidelines
above.
How much it makes depends on the feed water supply pressure, temperature, and quality.
The
carbon prefilter
and
postfilter
are replaceable cartridges. The
prefilter
removes chlorine while also filtering
sediments. The
postfilter
removes any other undesirable tastes and odors before you use the water.
Incoming Water ph
WATER SOFTENER RECOMMENDED
INCOMING WATER HARDNESS (GPG)
60
50
40
30
2010
8
6
7
7.5
6.5
Water Softener
not required
Customer Service Troubleshooting Tips
Operating Instructions
Safety Instructions
Installation Instructions
Customer Service Troubleshooting Tips
Installation Instructions
Safety Instructions
Operating Instructions
Customer Service Troubleshooting Tips
Installation Instructions
Safety Instructions
Operating Instructions
Maximum iron, manganese, hydrogen sulfide (ppm) . . . . . . . . . . . . . . . . . . . . . . . . . . . .<0.1
Chlorine in water supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Allowable
b
Feed water pH limits (pH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4–10
Product (quality) water, 24 hours—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10.0
a
Process water per gallon of product water, 24 hours—gallons . . . . . . . . . . . . . . . . . .5
Percent refection of TDS (new membrane) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92
a
Cyst reduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99.95%
Storage tank capacity—gallons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1.3
Automatic shutoff control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .yes
Prefilter and postfilter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12PA) Carbon Block
Reverse Osmosis membrane . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(FX12M) Thin Film Polyamid
Dimensions (inches) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .height 16“ width 17” depth 6”
Feed water pressure limits—pounds per square inch (psi) . . . . . . . . . . . . . . . . . . . . . .40–125
c
Feed water temperature limits—minimum/maximum degrees F. . . . . . . . . . . . . . . . . .40–100
Maximum Total Dissolved Solids (TDS)—parts per million (ppm) . . . . . . . . . . . . . . . .2000
Maximum water hardness @ 6.9 pH—grains per gallon (gpg) . . . . . . . . . . . . . . . . . . .10
For water with hardness greater than 10 grains (at 6.9 pH) the use of a softener
is recommended. Failure to install a water softener will reduce the life of the
Reverse Osmosis membrane. See chart for additional information on the
possible need for a water softener.
a. Tested by NSF International according to ANSI/NSF Standard 58 has given 7.1 GPD. Source water test
parameters are 50 psig, 77°F, pH of 7.5 ± 0.5, and 750 ppm total dissolved solids.
b. Removed (maximum of 2.0 ppm) by the Reverse Osmosis prefilter.
REGULAR MAINTENANCE IS
REQUIRED.
Chlorine will destroy the Reverse Osmosis membrane.
c. If house water pressure is over 125 psi, install a pressure reducing valve in the water supply line. If house
water pressure is under 40 psi, install a Reverse Osmosis booster pump (contact your local plumbing
supply company).