45
12
If an external prelter is present, drain the housing
through the mini ball valve on the bottom and use the red
button on the top of the external prelter head. Remove the
plastic wrap from a new prelter cartridge and insert into
housing. Tighten the external prelter housing to the external
prelter head.
13
Open the inlet valve and ll the system. Watch for leaks.
Open the outlet valve and a nearby cold water high demand
tap. Have the homeowner continue to run the cold water tap
for 30 minutes.
NOTE: If the winterization spring start up is combined with the
annual maintenance cleaning procedure, have the homeowner
continue to run a cold water tap for 60 minutes instead of 30
minutes. This is required to meet NSF drinking water standards
and to remove residual chlorine. The homeowner may notice a
chlorine taste/smell when a tap is rst opened for a day or two
following this procedure.
I. TROUBLESHOOTING
If there are any problems with the Homespring Water Purier System, contact your dealer or Homespring Customer
Service immediately.
Area Problem/Situation Corrective Action/Remedy
General
A part is missing
Contact customer service.
Purchase part (most are standard hardware parts) from local
hardware store.
System leaks water
Tighten system cap.
Check O-ring is in place, is clean and is intact.
Ensure connections are tight.
Replace broken part from an over tightened connection.
Rewrap thread connections with new plumber tape. Do not
reuse plumber tape.
System water ow is noticeably
reduced
Check if thimble lter is clogged. Depressurize system, remove
system cap and internal prelter, remove thimble lter using
a pair of needle nose pliers, clean thimble lter and reinsert
thimble lter.
Check if external prelter is clogged, if installed. Refer to
L. REPLACEMENT PART LIST AND PROCEDURES.
Check if Internal Prelter is clogged. Refer to
L. REPLACEMENT PART LIST AND PROCEDURES.
Check trans membrane pressure and perform a cleaning if
necessary as described in G. ANNUAL MAINTENANCE.
Check if drain solenoid valve functions. A malfunctioning
valve will increase the rate of the membrane fouling. Refer to
Controller Functions section, initiate a manual ush and verify
drain solenoid valve is working. Replace valve if necessary.
Water does not ow through system
Black cap on air relief valve must be backed o by 1.5 turns from
tight to allow air in and out of system.
If a surface water option kit is installed, check if inlet solenoid
valve is in the normally open position. Using the controller,
initiate a manual ush sequence while simultaneously pressing
the down arrow and hold for a full 5 seconds. Refer to Controller
Functions section for how to perform a manual ush sequence.
A buzz sound should be heard from the inlet solenoid valve.
Replace valve if necessary.

Other manuals for GE Homespring

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Homespring and is the answer not in the manual?

GE Homespring Specifications

General IconGeneral
BrandGE
ModelHomespring
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals