45
12
If an external prelter is present, drain the housing
through the mini ball valve on the bottom and use the red
button on the top of the external prelter head. Remove the
plastic wrap from a new prelter cartridge and insert into
housing. Tighten the external prelter housing to the external
prelter head.
13
Open the inlet valve and ll the system. Watch for leaks.
Open the outlet valve and a nearby cold water high demand
tap. Have the homeowner continue to run the cold water tap
for 30 minutes.
NOTE: If the winterization spring start up is combined with the
annual maintenance cleaning procedure, have the homeowner
continue to run a cold water tap for 60 minutes instead of 30
minutes. This is required to meet NSF drinking water standards
and to remove residual chlorine. The homeowner may notice a
chlorine taste/smell when a tap is rst opened for a day or two
following this procedure.
I. TROUBLESHOOTING
If there are any problems with the Homespring Water Purier System, contact your dealer or Homespring Customer
Service immediately.
Area Problem/Situation Corrective Action/Remedy
General
A part is missing
Contact customer service.
Purchase part (most are standard hardware parts) from local
hardware store.
System leaks water
Tighten system cap.
Check O-ring is in place, is clean and is intact.
Ensure connections are tight.
Replace broken part from an over tightened connection.
Rewrap thread connections with new plumber tape. Do not
reuse plumber tape.
System water ow is noticeably
reduced
Check if thimble lter is clogged. Depressurize system, remove
system cap and internal prelter, remove thimble lter using
a pair of needle nose pliers, clean thimble lter and reinsert
thimble lter.
Check if external prelter is clogged, if installed. Refer to
L. REPLACEMENT PART LIST AND PROCEDURES.
Check if Internal Prelter is clogged. Refer to
L. REPLACEMENT PART LIST AND PROCEDURES.
Check trans membrane pressure and perform a cleaning if
necessary as described in G. ANNUAL MAINTENANCE.
Check if drain solenoid valve functions. A malfunctioning
valve will increase the rate of the membrane fouling. Refer to
Controller Functions section, initiate a manual ush and verify
drain solenoid valve is working. Replace valve if necessary.
Water does not ow through system
Black cap on air relief valve must be backed o by 1.5 turns from
tight to allow air in and out of system.
If a surface water option kit is installed, check if inlet solenoid
valve is in the normally open position. Using the controller,
initiate a manual ush sequence while simultaneously pressing
the down arrow and hold for a full 5 seconds. Refer to Controller
Functions section for how to perform a manual ush sequence.
A buzz sound should be heard from the inlet solenoid valve.
Replace valve if necessary.