47
J. SPECIFICATIONS
Parameter UFC 211/ UF 211
Maximum continuous ow rate 4.5 gpm (17 Lpm)
Pressure drop at maximum continuous
ow rate when new, at 25°C
2
5 psi (34.5 kPa)/
4 psi (27.6 kPa)
Daily water volume treatment capacity
3
5,000 gal
(18,927 L)
GAC water volume capacity at maximum
continuous ow rate
130,000 gal
6
(491,400 L)
Maximum working pressure 100 psi (690 kPa)
Minimum working pressure 30 psi (207 kPa)
Maximum water temperature 100°F (38°C)
Minimum water temperature >32°F (>0°C)
Maximum ambient temperature 140°F (60°C)
Minimum ambient temperature >32°F (>0°C)
Operating pH range 6-10.5
Flush volume per day
5
7.5-19.5 gal
(28.4-73.7 L)
System eciency 94%-97%
4
Recommended maximum peak ow rate
1
11 gpm (42 Lpm)
Controller voltage 24 VDC
Inlet port (female) 3/4-14 NPT
Outlet port (female) 3/4-14 NPT
Drain port (female) 1/2-14 NPT
Vertical mount footprint: 18" x 18" (45 x 45 cm)
Vertical mount installation height: 74" (188 cm)
Horizontal mount footprint: inches (cm) 24" x 74" (61 x 188 cm)
Horizontal mount installation height: 36" (91 cm)
Shipping weight 82 lbs (37.3 kg)
Shipping dimensions W x H x L 15.5 x 16 x 72.5 in
(39.4 x 40.6 x 184.2 cm)
1
Chlorine reduction claims are based on a continuous ow of 4.5
gpm (17 Lpm).
2
Pressure drops are given for systems when they are new and
equipped as specied by the model number. At temperatures below
77°F (25°C) the pressure drop will be higher and at temperatures higher
than 77°F (25°C) the pressure drop will be lower.
3
Daily water volume capacity is dependent on water quality.
4
The UFC 211 and UF 211 Systems are equipped with a controller
that can operate the ush/drain sequence from once per day
to once per hour. The eciency numbers assume that the ush
program is run once per day.
5
Flush volumes are based on a drain ow rate of 5 gpm (18.9 Lpm).
6
Applicable to model UFC 211 only.
Controller Specications
Advanced Plus Controller
• Fuse - 3.0 Amp
• Voltage In - 24 VDC
• Voltage Output - 24 VDC
• Number of Outputs - 2
Program Estimated Water Use
1
Cleaning Cycle
2
1 7.5 gal (28.4 L) 2 ush/backpulse cycles
2 15 gal (56.7 L) 4 ush/backpulse cycles
3 13.5 gal (51 L) 2 ush/backpulse cycles,
1 drain cycle
4 19.5 gal (73.7 L) 2 ush/backpulse cycles,
2 drain cycles
1
Water use is based on the assumption that the drain ow
rate is 5 US gpm.
2
The Advanced Plus controller is capable of running the
cleaning cycle once, twice, four times, eight times or 24 times
per day. The water usage estimate assumes the controller is
running the cleaning cycle once per day.