EasyManuals Logo
Home>GE>Ranges>PD968SPSS

GE PD968SPSS User Manual

GE PD968SPSS
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
5
InstallationInstructions
WARNINGElectric Shock Hazard
Thisappliancemustbeproperlygrounded.
Donotuseanextensioncord.
Beforeinstallingrange,switchpoweroffattheservicepanelandlocktheservicedisconnectingmeans
topreventpowerfrombeingswitchedonaccidentally.Whenthedisconnectionmeanscannotbelocked,
securelyfastenaprominentwarningdevice,suchasatag,totheservicepanel.
Failuretofollowtheseinstructionsmayresultinseriousinjuryordeath.
WARNINGFire Hazard
Improperconnectionofaluminumhousewiringtocopperleadscanresultinanelectricalorfirehazard.If
residenceleadsarealuminum,useonlyconnectorsdesignedforjoiningcoppertoaluminumandfollowthe
manufacturer’srecommendedprocedureclosely.Failuretodosomayresultinseriousinjuryordeath.
5A
ELECTRICAL REQUIREMENTS
Werecommendyouhavetheelectricalwiringandhookupoftheapplianceconnectedbyaqualified
electrician.Afterinstallation,havetheelectricianshowyouhowtodisconnectpowerfromtheappliance.
Youmustuseasingle-phase,120/208VACor120/240VAC,60Hertzelectricalsystem.
EffectiveJanuary1,1996,theNationalElectricalCoderequiresthatnewconstruction(notexisting)utilizea
four-conductorconnectiontoanelectricoven.Wheninstallinganelectricoveninnewconstruction,amobile
home,recreationalvehicleorareawherelocalcodesprohibitgroundingthroughtheneutralconductor,refer
tothesectiononfour-conductorbranchcircuitconnections.
Checkwithyourlocalutilitiesforelectricalcodeswhichapplyinyourarea.Failuretowireyourovenaccording
togoverningcodecouldresultinahazardouscondition.Iftherearenolocalcodes,yourovenmustbewired
andfusedtomeettheNationalElectricalCode,NFPANo.70-latestedition,availablefromtheNationalFire
ProtectionAssociation.
Ratingplateislocatedonovenfrontframeandisvisiblewhenovendoorisopen.
Thisappliancemustsuppliedbewiththepropervoltageandfrequency,andconnectedtoanindividual,
properlygrounded,40amp(minimum)branchcircuitprotectedbyacircuitbreakerortime-delayfuse.
DO
NOTshortentheflexibleconduit.Theconduitstrainreliefclampmustbesecurelyattachedtothejunction
boxandtheflexibleconduitmustsecurelyattachedtotheclamp.Iftheflexibleconduitwillnotfitwithinthe
clamp,donotinstalltheovenuntilaclampofthepropersizeisobtained.
The3powerleadssuppliedwiththisappliancearesuitableforconnectiontoheaviergaugehousehold
wiring.Theinsulationofthese3leadsisratedfortemperaturesmuchhigherthanthetemperatureratingof
thehouseholdwiring.Thecurrent-carryingcapacityoftheconductorisgovernedbythewiregaugeandthe
temperatureratingoftheinsulationaroundthewire.

Other manuals for GE PD968SPSS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE PD968SPSS and is the answer not in the manual?

GE PD968SPSS Specifications

General IconGeneral
BrandGE
ModelPD968SPSS
CategoryRanges
LanguageEnglish

Related product manuals