strona 4 INSTRUKCJA SERWISOWA GHC201.07 i GHC201.08
PPUH „GECO” Sp. z o.o. Wydanie I OD DNIA 2018-02-22
Tabela 1: Marking of transformers and carrying capacity of outlets
Wyjście
Obciążalność
P1 Uniwersal
4A
750W
P2 Uniwersal
2A
450W
Uwaga !!!
Total power consumed at once by appliances must not exceed 10A !!!
III. HOW TO ORDER
In the order you have to give the full name of the controller in accordance with the marking defined in ‘II’
For example.:
GHC201.07 one-relay thermostat
GHC201.08 two-relay thermostat
Additionally you need to give a number and a length of temperature sensors . Standard length of sensors:
2,5m and 3,0m.
IV. INSTALLATION AND CONNECTION OF GHC201.08
1. Cut a hole with dimensions 28x70 mm in the appliance in the place marked accordingly.
2. All metal elements through which GHC201 or its cables are put should be filed or protected otherwise. I is
not permitted to fix GHC201 in a way which allows direct contact with water (e.g. condensing water on
the lower cover of the display), touching of evaporator outlet pipe etc. and causes considerable changes
of its temperature in comparison with air temperature (e.g. fixing in direct vicinity of the compressor and
its accessories, cooling and heated elements).
3. When GHC201.08 is fixed, power cables should be connected in accordance with the description on the
casing. In the case of versions GHC201.07 with one relay, the output of the other relay will be unused - it
will be marked with a cross on the label with the description - no wires should be connected to these
outputs !!!
4. Connectors have certification for permanent load 16A !!! They are provided with fine thread and special
plates preventing cutting of cables, therefore, when lightly screwed together they will have maximally
good contact and if more force is applied, it may damage the thread. In result the socket may be melted
and there might be a short circuit!!!
5. The whole unnecessary length of cables is shortened by cutting or winding and clipping together by
special plastic bands. Cable have to be well-fastened along their whole length and may not touch the
compressor and its accessories.