11-5. Floor type
PCB
P 190
CN
20
CN 14
CN 15CN 21
CN
22
CN 23
Indoor unit PCB
PCB External input External output Connector Input signal
Indoor unit
Operation/Stop
CN14
EdgeForced stop
Forced thermostat off CN15
Operation status
CN20/CN21/
CN22/CN23
Error status
Indoor unit fan
operation status
External heater output
¢
External input
With using external input function, some functions on this product can be controlled from an external
device.
“Operation/Stop” mode can be selected with function setting of indoor unit.
A twisted pair cable (22AWG) should be used. Maximum length of cable is 150 m.
The wire connection should be separate from the power cable line.
Indoor unit
Indoor unit functions such as Operation/Stop can be done by using indoor unit connectors.
1
2
3

Connector
(CN14/CN15)
PCB
Connected unit
*1: The switch can be used on the following condition: DC 12 V to24 V,1 mA to15 mA.
- 177 -
11-5. Floor type
11. External input and output
4-5 UNIT
MULTI-SPLIT TYPE
4-5 UNIT
MULTI-SPLIT TYPE