2-6. Ceiling type
Model name ABHG18KRTA ABHG22KRTA
Power supply 1Ø 230 V ~50 Hz
Available voltage range 198—264 V
Capacity kW class 5.0 6.0
Input power W 37 46
Running current A 0.21 0.25
Fan
Airflow rate
Cooling
HIGH
m
3
/h
840 900
MED 790 790
LOW 710 710
QUIET 650 650
Heating
HIGH 840 900
MED 790 790
LOW 710 710
QUIET 650 650
Type × Q'ty Sirocco × 2
Motor output W 50 50
Sound pressure level *
Cooling
HIGH
dB (A)
38 42
MED 36 37
LOW 33 34
QUIET 31 31
Heating
HIGH 38 42
MED 36 37
LOW 33 34
QUIET 31 31
Sound power level
Cooling
dB (A)
53 57
Heating 53 57
Heat exchanger type
Dimensions (H × W × D) mm 294 × 715 × 39.9
Fin pitch mm 1.30
Rows × Stages 3 × 14
Pipe type Copper
Fin type Aluminum
Enclosure
Material Steel sheet
Color
White
Approximate color of Munsell N9.25/
Dimensions
(H × W × D)
Net
mm
235 × 1,080 × 705
Gross 330 × 1,165 × 825
Weight
Net
kg
24 24
Gross 33 33
Connection
pipe
Size
Liquid
mm (in)
Ø6.35 (Ø1/4)
Gas Ø12.70 (Ø1/2)
Method Flare
Drain hose
Material PVC
Tip diameter mm Ø25 (I.D.), Ø32 (O.D.)
Operation range
Cooling
°C 18 to 32
%RH 80 or less
Heating °C 16 to 30
Remote controller type
Wired remote controller, Wireless remote controller, Mobile app*3 (FGLair
â„¢
)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *: Sound pressure level:
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
- 20 -
2-6. Ceiling type
2. Specifications
4-5 UNIT
MULTI-SPLIT TYPE
4-5 UNIT
MULTI-SPLIT TYPE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the General AUXG07KVLA and is the answer not in the manual?

General AUXG07KVLA Specifications

General IconGeneral
BrandGeneral
ModelAUXG07KVLA
CategoryAir Conditioner
LanguageEnglish

Related product manuals