EasyManuals Logo
Home>Global>Fire Alarms>JUNO-NET

Global JUNO-NET User Manual

Global JUNO-NET
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
OPERATION JUNO-NET
1.10 DISABLEMENTS
1.10.1 SELECTED DETECTORS
STATUS
FIRE ALARM SYSTEM
FIRE
FAULT
PRE-ALARM
TEST
DISABLED
SYSTEM ON
ALARM FAULT
SUPPLY FAULT
PROC. FAULT
TRANS. FAULT
SOUND ALARMS
PAPER FEED
LAMP TEST
SYSTEM RESET
ALARM SILENCE
DISABLED
TEST
FAULT
FIRE
AUXILIARY
RELAYS
FIRE BRIGADE
TRANSMISSION
SELECTED
DETECTORS
ACTIVE
DELAYS
FIRE BRIGADE
ACKNOWLEDGED
ALARM DISPLAY
JUNO-NET
MANUFACTURED TO THE
REQUIREMENTS OF
EN54 Pt 2 & Pt 4 1999
FAULTS
CONTROLS
DISABLEMENTS
QUEUE REVIEW
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
21
23
22
20
25
24
27
26
29
30
32
33
31
28
34
35
LCD DISPLAY
STATUS
FIRE ALARM SYSTEM
FIRE
FAULT
PRE-ALARM
TEST
DISABLED
SYSTEM ON
ALARM FAULT
SUPPLY FAULT
PROC. FAULT
TRANS. FAULT
SOUND ALARMS
PAPER FEED
LAMP TEST
SYSTEM RESET
ALARM SILENCE
DISABLED
TEST
FAULT
FIRE
AUXILIARY
RELAYS
FIRE BRIGADE
TRANSMISSION
SELECTED
DETECTORS
ACTIVE
DELAYS
FIRE BRIGADE
ACKNOWLEDGED
ALARM DISPLAY
JUNO-NET
MANUFACTURED TO THE
REQUIREMENTS OF
EN54 Pt 2 & Pt 4 1999
FAULTS
CONTROLS
DISABLEMENTS
QUEUE REVIEW
1
2
3
4
6
7
8
9
10
11
12
13
14
15
16
17
18
19
21
23
22
20
24
27
26
29
30
32
33
31
28
34
35
LCD DISPLAY
SELECTED
DETECTORS
When activated:
The SELECTED DETECTORS will be illuminated
The STATUS - DISABLED will be illuminated
The QUEUE REVIEW - DISABLED will be illuminated
The disabled detectors can be reviewed using the
DISABLED QUEUE REVIEW
The SELECTED DETECTORS button will only operate if
there is at least one detector set to SELECTIVE
DISABLEMENT.
Re-pressing the SELECTED DETECTORS button again
will re-enable the detectors.
LED
LED
LED
button
Using the programming functions (see the ‘Installation & Commissioning Manual’) individual detectors can be set for
SELECTIVE DISABLEMENT. When the SELECTED DETECTORS button is activated those detectors will be disabled. (This may be
required, for example, in a building with smoke detectors inside a room reserved for cigarette smokers. During the day it would
be wise to disable these detectors in order to prevent the obvious false alarms it would otherwise generate.)
12
OPERATION & MAINTENANCE MANUAL
REVISION 0.7a
16-04-2004

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Global JUNO-NET and is the answer not in the manual?

Global JUNO-NET Specifications

General IconGeneral
BrandGlobal
ModelJUNO-NET
CategoryFire Alarms
LanguageEnglish