[1] For Belgium Max. Output Apparent Power (VA), GW4K-DT is 4000; GW5K-DT is 5000; GW6K-DT is 6000; GW8K-DT is 8000;
GW10KT-DT is 10000; GW12KT-DT is 12000; GW15KT-DT is 15000;
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Technical Data
PV Input Data
Max. DC Power (W)
Max. DC Input Voltage (V) [1]
MPPT Range (V)
Start-up Voltage (V)
Min. Feed-in Voltage(V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
No. of MPP Trackers
No. of Input Strings Per MPP Tracker
AC Output Data
Nominal Output Power (W)
Max. Output Apparent Power (VA)
Nominal Output Voltage (V)
Nominal Ouput Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Efficiency
Max. Efficiency
Europe Efficiency
Protection
Anti-islanding Protection
Input Reverse Polarity Protection
Insulation Resistor Detection
DC Surge Protectioin
AC Surge Protectioin
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Output Over Voltage Protection
General Data
Operating Temperature Range (℃)
Relative Humidity
Operating Altitude (m)
Cooling
User Interface
Communication
Weight (kg)
Size (Width*Height*Depth mm)
Protection Degree
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC
Integrated
Integrated
Integrated
Integrated(Type III)
Integrated(Type III)
Integrated
Integrated
Integrated
Integrated
-30~60
0~100%
≤4000
Fan Cooling
LCD&LED
WiFi or LAN
15
354*433*147
IP65
<1
Transformerless
Visit homepage to achieve information.
GW12K-DT
18000
1000
180~850
160
210
620
12.5/12.5
15.6/31.2
2
1/2
12000
13200
400, 3L/N/PE
50/60
20.3
<3%
98.3%
97.7%
GW15KT-DT
22500
1000
180~850
160
210
620
12.5/25
15.6/31.2
2
1/2
15000
16500
400, 3L/N/PE
50/60
24
<3%
98.3%
97.7%
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Technical Data
PV Input Data
Max. DC Power (W)
Max. DC Input Voltage (V) [1]
MPPT Range (V)
Start-up Voltage (V)
Min. Feed-in Voltage(V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
No. of MPP Trackers
No. of Input Strings Per MPP Tracker
AC Output Data
Nominal Output Power (W)
Max. Output Apparent Power (VA) [1]
Nominal Output Voltage (V)
Nominal Ouput Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Efficiency
Max. Efficiency
Europe Efficiency
Protection
Anti-islanding Protection
Input Reverse Polarity Protection
Insulation Resistor Detection
DC Surge Protectioin
AC Surge Protectioin
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Output Over Voltage Protection
General Data
Operating Temperature Range (℃)
Relative Humidity
Operating Altitude (m)
Cooling
User Interface
Communication
Weight (kg)
Size (Width*Height*Depth mm)
Protection Degree
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC
Integrated
Integrated
Integrated
Integrated(Type III)
Integrated(Type III)
Integrated
Integrated
Integrated
Integrated
-30~60
0~100%
≤4000
LCD&LED
WiFi or LAN
15
354*433*147
IP65
<1
Transformerless
Visit homepage to achieve information.
GW6K-DT
9000
1000
180~850
160
210
620
12.5/12.5
15.6/15.6
2
1/1
6000
6600
400, 3L/N/PE
50/60
9.6
<3%
98.2%
97.6%
GW6KL-DT
9000
600
180~550
160
210
480
12.5/12.5
15.6/15.6
2
1/1
6000
6600
400, 3L/N/PE
50/60
9.6
<3%
98.0%
97.5%
GW8K-DT
12000
1000
180~850
160
210
620
12.5/12.5
15.6/15.6
2
1/1
8000
8800
400, 3L/N/PE;
50/60
12.8
<3%
98.2%
97.6%
GW10KT-DT
15000
1000
180~850
160
210
620
12.5/12.5
15.6/15.6
2
1/1
10000
11000
400, 3L/N/PE
50/60
16
<3%
98.3%
97.7%
Natural Cooling Fan Cooling
27 28