7 Technical Parameters
~1 (Adjustable from 0.8 leading to 0.8 lagging)
Technical Data
PV Input Data
Max. DC Power (W)
Max. DC Input Voltage (V) [1]
MPPT Range (V)
Start-up Voltage (V)
Min. Feed-in Voltage(V)
Nominal DC Input Voltage (V)
Max. Input Current (A)
Max. Short Current (A)
No. of MPP Trackers
No. of Input Strings Per MPP Tracker
AC Output Data
Nominal Output Power (W)
Max. Output Apparent Power (VA) [1]
Nominal Output Voltage (V)
Nominal Ouput Frequency (Hz)
Max. Output Current (A)
Output Power Factor
Output THDi (@Nominal Output)
Efficiency
Max. Efficiency
Europe Efficiency
Protection
Anti-islanding Protection
Input Reverse Polarity Protection
Insulation Resistor Detection
DC Surge Protectioin
AC Surge Protectioin
Residual Current Monitoring Unit
Output Over Current Protection
Output Short Protection
Output Over Voltage Protection
General Data
Operating Temperature Range (℃)
Relative Humidity
Operating Altitude (m)
Cooling
User Interface
Communication
Weight (kg)
Size (Width*Height*Depth mm)
Protection Degree
Night Self Consumption (W)
Topology
Certifications & Standards
Grid Regulation
Safety Regulation
EMC
Integrated
Integrated
Integrated
Integrated(Type III)
Integrated(Type III)
Integrated
Integrated
Integrated
Integrated
-30~60
0~100%
≤4000
Natural Cooling
WiFi or LAN
LED or LCD
15
354*433*147
IP65
<1
Transformerless
Visit homepage to achieve information.
GW5K-DT
7500
1000
180~850
160
210
620
12.5/12.5
15.6/15.6
2
1/1
5000
5500
400, 3L/N/PE
50/60
8
<3%
98.2%
97.6%
GW4K-DT
6000
1000
180~850
160
210
620
12.5/12.5
15.6/15.6
2
1/1
4000
4400
400, 3L/N/PE
50/60
6.4
<3%
98.2%
97.6%
GW4KL-DT
6000
600
180~550
160
210
480
12.5/12.5
15.6/15.6
2
1/1
4000
4400
400, 3L/N/PE;
50/60
6.4
<3%
98.0%
97.5%
GW5KL-DT
7500
600
180~550
160
210
480
12.5/12.5
15.6/15.6
2
1/1
5000
5500
400, 3L/N/PE
50/60
8
<3%
98.0%
97.5%
Note:
When sunlight is insufficient, the PV inverter may continuously start up and shut down automati-
cally due to insufficient power generation by the PV panels, which would not lead to inverter
damage. If the problem still exists, please call the local service office.
1. Turn off DC switch of the inverter.
2. Wait till the inverter's LCD light is off.
3. Turn on DC switch and make sure it is connected.
4. If the problem still exists, contact local service office for help.
1. Turn off DC switch, take off DC connector, measure the voltage of PV array.
2. Plug in DC connector, and turn on DC switch.
3. If PV array voltage is lower than 250V , please check configuration of inverter
module.
4. If voltage is higher than 250V , please contact local office.
Type of fault Troubleshooting
Relay-Check Failure
DCI Injection High
EEPROM R/W Failure
SPI Failure
DC BUS High
GFCI Failure
No display
Inverter
Failure
Others
25 26