3.2 Inverter Overview
MT series inverter illustration.
Note: Image shown here is for reference only; actual product you receive may be different.
The number of strings per MPPT is different. Refer to the Technical Specification to check more
details.
IT
L1
L2
L3
Transformer
PE
Inverter
GW70KHV-MT / GW80KHV-MT and GW80KBF-MT support the IT grid type. Refer to the below figure.
Item
1
2
3
4
5
6
7
8
9
10
11
12
Name
PV Input Terminal
RS485 Communication Port
AC Output Terminal
Wi-Fi Port (Optional)
GPRS Port (Optional)
Fans
DC Switch (Optional)
Indicator light
LCD
Button
Air Outlet
External Protection
Grounding Terminal
Description
For DC cable connection
For RS485 communication cable connection
For AC cable connection
For Wi-Fi module connection
For GPRS module connection
There are six fans to perform controlled force-air cooling.
During normal operation, it is in the ' on ' state; it can shut down
the inverter after it is disconnected from the grid at the AC breaker.
Display the state of the inverter
Inverter operation data viewing and parameter configuration.
The LCD is equipped in some models only.
For configuration and viewing parameters.
Exit of hot air during the inverter operation.
Second protection earth terminals as specified in EN50178.
1. PV Input Terminal
2. RS485 Communication Port
3. AC Output Terminal
4. WiFi Port (Optional)
586
788
267
5. GPRS Port (Optional)
6. Fans
7. DC Switch (Optional)
1 2
4
5
3
8
6
7
9
10
8. Indicator Light
9. Air Outlet
10. External Protection
Grounding Terminal
GW30KLV-MT/GW35KLV-MT/GW50KLV-MT/GW50KN-MT/GW60KN-MT/GW50KBF-MT/GW70KHV-MT/GW50KBF-MT-KR/
GW60KBF-MT-KR
586mm
788
1 2
4 5
3
9
6
8 10
7
264
11
12
1. PV Input Terminal*
2. RS485 Communication Port
3. AC Output Terminal
4. WiFi Port (Optional)
5. GPRS Port (Optional)
6. Fans
7. DC Switch (Optional)
8. Indicator Light
9. LCD
10. Button
11. Air Outlet
12. External Protection
Grounding Terminal
GW60KBF-MT/GW75KBF-MT/GW80KBF-MT/GW80KHV-MT/GW75K-MT/GW80K-MT