7
Technical Information
Service Manual
2.2 Operation Characteristic Curve
2.3 Capacity Variation Ratio According to Temperature
Cooling
Heating
0
09070605040302010
1
10
210010908070605040302010
80
11
10
9
8
7
6
5
4
3
2
1
0
11
10
9
8
7
6
5
4
3
2
1
0
• Conditions
Indoor : DB27˚C/WB19˚C
Outdoor : DB35˚C/WB24˚C
Indoor air flow : High
Pipe length : 5m
• Conditions
Indoor : DB20˚C/WB15˚C
Outdoor: DB7˚C/WB6˚C
Indoor air flow : High
Pipe length : 5m
220V
230V
240V
220V
230V
240V
Current (A)
Current (A)
Compressor frequency(Hz)
Compressor frequency(Hz)
gnilooC
Capacity ratio(%)
Outdoor temp.(°C)
gnitaeH
Capacity ratio(
%)
Outdoor temp.(°C)
0
20
40
60
80
100
120
140
-15-10 -5 0510 15 20 25 30 35 43
0
20
40
60
80
100
120
140
-22 -15 -10 -7 0 2 7 15 18 21 24
Conditions
Indoor:DB20°C
Indoor air flow:Super High
Pipe length:5m
Condition
Indoor:DB27°C WB19°C
Indoor air flow:
High
Pipe length:5m