94
Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Step Procedure
Before disassemble
Turn off the air conditioner and disconnect the power
before disassemble the air conditioner.
1. Remove lter
Hold the handle on the lter, pull it upwards to let the
clasp at the top part of the lter loose, push it forwards
and then the lter can be pulled out.
2. Remove guide louver
Push out the plug pin on guide louver, bend the guide
louver with hand and then separate the guide louver
from the crank shaft of step motor to remove it.
Filter
Guide Louver
Guide Louver
ATD/ATE