)XQFWLRQDQG&RQWURO
(2)Dry Mode
Dry Conditions and Process
When Tamb.
Tpreset+2 , the unit will run in dry and cooling mode, in that case the compressor and outdoor fan will run and
the indoor fan will run at low speed.
When Tpreset-2
Tamb. Tpreset+2 , the unit will run in dry mode, in that case, the indoor fan will run at low speed, the
compressor and the outdoor fan will be stopped in 6 min. After 4 min, the compressor and the outdoor fan will be restarted. Dry
process is cycled as the above.
When Tamb.
Tpreset-2 , the compressor and the outdoor fan will stop working and the indoor fan will run at low speed.
In this mode, the four-way valve is de-energized, and setting temperature range is between 16
30 . The displayer will display
running and drying icons and setting temperature.
Tpreset+2
T
preset 2
Cooling
Dehumidfying
Stop
min
.
min.
min.
min.
Outdoor fan
Compressor
Indoor fan
Low speed
Run
Stop
Protection
Freeze potection
If freeze protection of the system is detected in dry and cooling mode, the compressor and the outdoor fan will stop
running and the indoor fan will run at low speed. When the freeze protection is released and the compressor has been
stopped for 3 min, the complete unit will resume its previous running state. Upon the condition that the compressor runs for 6
min and stops for 4 min is met and freeze protection is detected, the compressor and the outdoor fan will stop running and
the indoor fan will run at low speed. When the freeze protection is released and the compressor has been stopped for 4
min, the complete unit will resume its previous running state.
Other protection
Other protections are the same as those in cooling mode.
T
amb.
(3)Heating mode
Heating conditions and process
When Tamb.
Tpreset+2 , the unit will run in heating mode, in that case, the four-way valve, the compressor and the outdoor
fan will run simultaneously. The indoor fan will delay at most 2mins to run. The indoor fan will run 2 mins delayed at most.
When Tamb
Tpreset+4 , the compressor and the outdoor fan will stop and the four-way valve will remain energized(keep
energizing) and the indoor fan will blow residual heat.
When T
preset
+2 T
amb.
T
preset
+4 , the unit will maintain its previous running state.
Under this mode, the four-way valve is energized, and setting temperature range is 16
30 . The displayer will display running
and heating icons and setting temperature.
Tpreset
Tpreset
Compressor
Outdoor unit
Indoor unit
4-way valve
min
stop heating
original operation status
start heating
Tamb.
min
min
min
setting
fan speed
setting
fan speed
min
Run
Stop

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWC12NB-D3NNB1A/I and is the answer not in the manual?

Gree GWC12NB-D3NNB1A/I Specifications

General IconGeneral
BrandGree
ModelGWC12NB-D3NNB1A/I
CategoryAir Conditioner
LanguageEnglish

Related product manuals