EasyManuals Logo

Gree GWH09TB-S3DNA1D/I User Manual

Gree GWH09TB-S3DNA1D/I
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
49
Service Manual
Installation and Maintenance
9.2 Procedure of Troubleshooting
1. Malfunction of Temperature Sensor F1, F2
●Indoor unit:
Troubleshooting for
F1,F2 malfunction
Is
the wiring terminal between the
temperature sensor and the controller
loosened or poorly contacted?
Insert the temperature
sensor tightly
Yes
Is malfunction
eliminated
Is there short circuit due to trip
-
over of
the parts?
Make the parts upright
Is malfunction
eliminated
Replace the mainboard
with the same model.
End
No
No
Is the
temperature sensor normal according
to the Resistance
Table?
No
Replace it with a
temperature sensor
with the same model
no
Yes
Ye
s
Is malfunction
removed
no
Yes
yes
no
Yes
Yes
No
No

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH09TB-S3DNA1D/I and is the answer not in the manual?

Gree GWH09TB-S3DNA1D/I Specifications

General IconGeneral
BrandGree
ModelGWH09TB-S3DNA1D/I
CategoryAir Conditioner
LanguageEnglish

Related product manuals