Protection
a. In cooling operation, protection is the same as that under the cooling mode;
b. In heating operation, protection is the same as that under the heating mode;
c. When ambient temperature changes, operation mode will be converted preferentially. Once started, the compressor will
remain unchanged for at least 6 minutes.
(6) Common Protection Functions and Fault Display under COOL, HEAT, DRY and AUTO Modes
Overload protection
T tube: measured temperature of outdoor heat exchanger under cooling mode; and measured temperature of indoor heat exchanger
under heating mode.
1) Cooling overload
a.If T tube≤52
o
C, the unit will return to its original operation state.
b.If T tube≥55
o
C, frequency rise is not allowed.
c.If T tube≥58
o
C, the compressor will run at reduced frequency.
d.If T tube≥62
o
C, the compressor will stop and the indoor fan will run at preset speed.
2) Heating overload
a.If T tube≤50
o
C, the unit will return to its original operation state.
b.If T tube≥53
o
C, frequency rise is not allowed.
c.If T tube≥56
o
C, the compressor will run at reduced frequency.
d.If T tube≥60
o
C, the compressor will stop and the indoor fan will blow residue heat and then stop.
Exhaust temperature protection of compressor
a.If exhaust temperature ≥98
o
C, frequency is not allowed to rise.
b.If exhaust temperature ≥103
o
C, the compressor will run at reduced frequency.
c.If exhaust temperature ≥110
o
C, the compressor will stop.
d.If exhaust temperature ≤90
o
Cand the compressor has stayed at stop for at least 3 minutes, the compressor will resume its operation.
Communication fault
If the unit fails to receive correct signals for durative 3 minutes, communication fault can be justied and the whole system will stop.
Module protection
Under module protection mode, the compressor will stop. When the compressor remains at stop for at least 3 minutes, the compressor will
resume its operation. If module protection occurs six times in succession, the compressor will not be started again.
Overload protection
If temperature sensed by the overload sensor is over 115
o
C, the compressor will stop and the outdoor fan will stop with a time lag of 30
seconds. If temperature is below 95
o
C, the overload protection will be relieved
o
C.
DC bus voltage protection
If voltage on the DC bus is below 150V or over 420V, the compressor will stop and the outdoor fan will stop with a time lag of 30 seconds.
When voltage on the DC bus returns to its normal value and the compressor has stayed at stop for at least 3 minutes, the compressor will
resume its operation.
Faults of temperature sensors
Designation of sensors Faults
Indoor ambient temperature
The sensor is detected to be open-circuited or short-circuited for successive 30
seconds
Indoor tube temperature
The sensor is detected to be open-circuited or short-circuited for successive 30
seconds
Outdoor ambient temperature
The sensor is detected to be open-circuited or short-circuited for successive 30
seconds
Outdoor tube temperature
The sensor is detected to be open-circuited or short-circuited for successive 30
seconds, and no detection is performed within 10 minutes after defrost begins.
Exhaust
After the compressor has operated for 3 minutes, the sensor is detected to be
open-circuited or short-circuited for successive 30 seconds.
Overload
After the compressor has operated for 3 minutes, the sensor is detected to be
open-circuited or short-circuited for successive 30 seconds.
Zero-crossing inspection circuit
malfunction of the IDU fan motor
Zero-crossing signal is not detected for continuously 3s; Or the interval between
the zero-crossing signals in 3s
25ms (power frequency: 50Hz)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH12QB-K6DNB8I and is the answer not in the manual?

Gree GWH12QB-K6DNB8I Specifications

General IconGeneral
BrandGree
ModelGWH12QB-K6DNB8I
CategoryAir Conditioner
LanguageEnglish

Related product manuals