Capacity ratio( )
%
2.3 Operation Data
Cooling
Temperature condition
(°C)
Model
name
Standard
pressure
Heat exchanger pipe temp.
Indoor fan
mode
Outdoor fan
mode
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
27/19 35/24
18K 0.8~0.9 in:8~11 out:11~12 in:75~85 out:37~43
Super High High
24K 0.8~1.0 in:8~11 out:11~14 in:75~85 out:36~43
NOTES :
(1) T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure of air pipe connecting indoor and outdoor units(on the side of gas pipe)
(2) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.(The rmistor the mometer)
(3) Connecting piping condition : 4m or 5m
Heating
Temperature condition
(°C)
Model
name
Standard
pressure
Heat exchanger pipe temp.
Indoor fan
mode
Outdoor fan
mode
Indoor Outdoor P (MPa) T1 (°C) T2 (°C)
20/- 7/6
18K 2.7~2.9 in:75~85 out:37~43 in:1~3 out:3~4
Super High High
24K 2.6~3.0 in:75~85 out:36~43 in:1~3 out:3~4