8
Air to Water Heat Pump
Service Manual- Versati Series
QSPEVDU
INDOOR UNIT
Model
GRS-CQ16Pd/
Na-K(I)
GRS-
CQ12Pd/
Na-M(I)
GRS-
CQ14Pd/
Na-M(I)
GRS-
CQ16Pd/
Na-M(I)
GRS-
CQ16Pd/
Na-H(I)
Product Code
ER010N1010 ER010N1060 ER010N1070 ER010N1080
ER010N1090
Power Supply
V,Ph,Hz
220-240V,~,50Hz
380-415V,3N~,50Hz
380V,3N~,60Hz
Rated input (indoor only) W 6200 6200
Liquid side diameter
mm
(inch)
9.52(3/8)
9.52(3/8)
Gas side diameter
mm
(inch)
15.9(5/8)
15.9(5/8)
2SHUDWLRQ5DQJH2XWÀRZ
water temp.)
Cooling (FCU)
7-25
7-25
Cooling (Floor )
18-25 18-25
Heating (FCU)
25-55(High Temperature Cycle)
Heating (Floor )
25-45 (Low Temperature Cycle)
Main
components
pump
Type - Water-cooled -
Nr. of speed - 3 -
Power input W 200 -
:DWHUÀRZ
limit
LPM 12 -
Expansion
Vessel
Volume Liter 10 10
Water Pressure
(Max)
Bar 3 3
Water Pressure
(Pre)
Bar 1 1
Electric
Heater
Type - Sheath Sheath
Material - Stainless Steel Stainless Steel
Operation - Automatic Automatic
Steps - 2 1 1
Capacity
Combination
KW 3+3 6 6
Power input
V,Ph,Hz
230V,~,50Hz 400V,3N~,50Hz
380V,3N~,60Hz
Heat
Exchanger
Type - Brazed Plate HEX
Brazed
Plate HEX
Quantity - 1 1
Outline Dimension(W×D× H) mm 900×500×324 900×500×324
Net Weight kg 53 53 53 53 49