9
Air to Water Heat Pump
Service Manual- Versati Series
QSPEVDU
4.1.3 Water Tank (optional)
Models SXVD200LCJ/A-K SXVD200LCJ2/A-K SXVD300LCJ/A-K SXVD300LCJ2/A-K
Product Code ER20000160 ER20000170 ER20000180 ER20000190
Models SXVD200LCJ/A-M SXVD200LCJ2/A-M SXVD300LCJ/A-M SXVD300LCJ2/A-M
Product Code ER20000240 ER20000260 ER20000250 ER20000270
Models SXVD200LCJ/A-H SXVD200LCJ2/A-H SXVD300LCJ/A-H SXVD300LCJ2/A-H
Product Code ER20000280 ER20000290 ER20000300 ER20000310
Water Tank Volume L 200 300
Electric Heater Power W 3000
Cool Water
Inlet Pipe
Outer
diameter
mm DN15
inch 1/2
Screw thread spec Ǝ)HPDOH%63
Hot Water
Outlet Pipe
Outer
diameter
mm DN15
inch 1/2
Screw thread spec Ǝ)HPDOH%63
Circulation Water
Inlet/Outlet Pipe
Outer
diameter
mm / DN20 / DN20
inch / 3/4 / 3/4
Screw thread spec / Ǝ)HPDOH%63 / Ǝ)HPDOH%63
Water Inlet/
Outlet(Heat
Pump) Pipe
Outer
diameter
mm DN20
inch 3/4
Screw thread spec Ǝ)HPDOH%63
2XWOLQH'LPHQVLRQĭ'î+ mm ĭî ĭî
Net Weight kg 68 71 82 87
Note :
Tank is optional part, and the specific model of tank shall be selected according to local weather and
professional suggestions.
4.2 Operation Range
Mode Range of Outdoor Temperature( )
Heating -20~35
Cooling 10~48
Water heating -20~45