H2SM-(9+12)HEK03/R2
Funcitions and Control
Domestic Air Conditioner
11
5. Funcitions and Control
0DLQIXQFWLRQVDQGFRQWUROVSHFL¿FDWLRQRILQGRRUXQLW
Note: See the list of functions for the functions applicable to different models.
5.1.1 Automatic running
:KHQWKHUXQQLQJPRGHLVWXUQHGWRDXWRPDWLRQDIWHUVWDUWLQJWKHV\VWHPWKHV\VWHPZLOO¿UVWGHWHUPLQH
the running mode according to the current room temperature and then will run according to the
determined mode. Tr in the following selection conditions means room temperature, Ts means setting
temperature, Tp means temperature of indoor coil pipe
7U& &KRRVHWKHFRROLQJPRGH
Tr<23°C Choose the warming mode
After turning to the automation mode, the running mode can be switched between cooling mode, fan
mode and heating mode according to the change of the indoor ambient temperature. But the automatic
conversion between cooling mode and heating mode must be conducted after 15 minutes.
5.1.2 Indoor temperature control
Temperature control range: 16°C---30°C
Temperature difference: ±1°C
Compressor can’t be controlled by temperature sensor within 2 minutes after it starts
1.Cooling mode:
:KHQ7U!7VRXWGRRUIDQPRWRUDQGFRPSUHVVRURQDQGLQGRRUIDQPRWRUUXQDW¿[HGZLQGVSHHG
When Tr< Ts, outdoor fan motor and compressor off, and when Tr > Ts, outdoor fan motor and
compressor are working again .If Tr=Ts, the indoor fan motor , outdoor fan motor and the compressor’s
state will not change.
2.Heating mode:
:KHQ7U7VFRPSUHVVRUIRXUZD\VYDOYHDQGRXWGRRUIDQPRWRULVRQLQGRRUIDQPRWRUUXQVDV
in cold blast avoidance mode, and 4°Cof compensation is added after compressor is started.
When Tr>Ts+5°C, compressor is off, and the indoor fan motor runs as in cold blast avoidance
mode.
When Tr<Ts+5°C, compressor, four-ways valve and outdoor fan motor is on, and the indoor fan
motor runs as in the mode of avoiding cold blast.
'HKXPLGL¿FDWLRQPRGH
The compressor, outdoor fan and indoor fan will run as per the following working pattern so as to realize
WKHUHIULJHUDWLQJUXQQLQJRIGHKXPLGL¿FDWLRQ
1) Tr> Ts+2°C, compressor, outdoor fan run continuously, indoor fan runs as per setting wind speed (State
1);
7V&7U7VFRPSUHVVRURXWGRRUIDQUXQLQWHUPLWWHQWO\ZLWKPLQXWHV21PLQXWHV2))
&RPSUHVVRUDQGRXWGRRUIDQDUHV\QFKURQRXVLQGRRUIDQUXQVLQ¿[HGORZHUZLQGVSHHGDQGZLOOFHDVH
at the stand-by time of 3 minutes (State 2)
3) Tr <Ts, compressor, outdoor fan ceases, indoor fan runs in lower wind speed. (State 3)